Anybus X-gateway - CANopen Master - CANopen Slave

Características destacadas

  • Fast copying of cyclic I/O data between two CANopen networks (5 ms)
  • Full CANopen Master/Manager functionality, eliminates the need for an additional PLC controller on the CANopen network
  • Connects up to 126 CANopen slave devices
  • Proven and tested with all PLC manufacturers
  • Easy CANopen configuration via the included Anybus Configuration Manager software. No programming required
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy

Descripción

The Anybus X-gateway CANopen provide a seamless connection between a CANopen upper network and a secondary CANopen sub-network. This makes it possible to extend CANopen network and devices without a secondary PLC system.

FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. I/O data from one CANopen network is written into CANopen objects that can be mapped into CANopen PDOs and vice versa. The gateway acts as a full CANopen Master/Manager on one side and a CANopen Slave on the other side. The data transmission between the two CANopen networks is completely transparent with a maximum data capacity of 510 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
CANopen configuration can easily be made through the included Anybus Configuration Manager CANopen software, or with any other standard CANopen configuration tool. No programming skills are needed. 

CANopen Master/Manager Interface

  • CANopen Master/Manager implementation according to the CANopen specification DS301 v4.0.2.
  • Connects up to 126 CANopen slaves
  • Network Management (NMT) messages, to configure and initialize the network.
  • Supporting 128 Receive PDOs and 128 Transmit PDOs, each can transfer up to 8 bytes.
  • Up to 510 bytes of cyclic data in each direction (PDO)
  • PDO message types: COS (Change of State), Cyclic Synchronous, Acyclic Synchronous.
  • Synchronization Object (SYNC) is used for synchronizing PDO communication.
  • Heartbeat Mechanism to monitor the status of nodes.
  • Node Guarding/Life Guarding Protocol provides possibility to guard slaves or the master.
  • EMCY (Emergency Object) is used for error reporting.
  • LSS master functionality
  • Can also function as a CANopen Slave

CANopen Slave interface

CANopen Slave settings can be made either via on-board switches, or by importing the provided .EDS file into engineering tool of the controlling PLC.

  • Complete CANopen slave functionality according to CANopen Version 4.02
  • Max 512 bytes of Input and 512 bytes of Output data (PDO + SDO)
  • Customizable PDO mapping
  • Up to 80 RPDO’s and 80 TPDO’s
  • Transmission types: PDO Sync, Change-of-state, Event based and RTR
  • Network store/restore functionality
  • Heartbeat & Node Guarding support
  • Supports CANopen baudrates 10 kbit/s – 1 Mbit/s
  • CANopen configuration via .EDS file or via on-board rotary switches
  • 1x D-sub 9-pin male CANopen connector
Order Code AB7827
Included components     Resource CD, Quick start guide, manuals. Anybus Configuration Manager CANopen software. For bulk pack orders, all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included)
Optional Accessories USB-CAN configuration adapter (Order Code 012670)  
Guarantee3 years 

Especificaciones Tecnicas

Dimensions (L•W•H) 120 x 75 x 27mm or 4,72 x 2,95 x 1,06"
Weight150g or 0,33 lbs
Operating temperature-25 to +55 °C or 0 to +131 °F
Storage temperature -40 to +85 °C or -40 to +185 °F
Power supply24 VDC
Current consumption Typical 150mA
Configuration portUSB (USB to CAN cable not included)
Configuration Switches On-board for CANopen node address and baud rate setting
CANopen connectorD-sub 9 Male (Included)
Fieldbus/Ethernet connector(See interface details above)
Galvanic isolation On both CAN and BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
CANopen baudrate20 kbit/s - 1 Mbit/s
CertificationsCE, CULUS, ATEX/Haz.Loc

Referencia Descripcion
AB7304 Anybus X-gateway - CANopen Master - CANopen Slave
Si continuas utilizando este sitio aceptas el uso de cookies. más información