Anybus X-gateway - CANopen Slave - Interbus CU Slave

Características destacadas

  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy

Descripción

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and Interbus networks.

FAST COPYING OF I/O DATA

The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Slave on both networks. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

CANopen Slave interface

CANopen Slave settings can be made either via on-board switches, or by importing the provided .EDS file into engineering tool of the controlling PLC.

  • Complete CANopen slave functionality according to CANopen Version 4.02
  • Max 512 bytes of Input and 512 bytes of Output data (PDO + SDO)
  • Customizable PDO mapping
  • Up to 80 RPDO’s and 80 TPDO’s
  • Transmission types: PDO Sync, Change-of-state, Event based and RTR
  • Network store/restore functionality
  • Heartbeat & Node Guarding support
  • Supports CANopen baudrates 10 kbit/s – 1 Mbit/s
  • CANopen configuration via .EDS file or via on-board rotary switches
  • 1x D-sub 9-pin male CANopen connector

Interbus CU Slave Interface

Interbus Slave address settings can are automatically detected by the controlling PLC.

  • Complete Interbus functionality according to EN 50170
  • Max. 20 bytes of process data (512 bytes with PCP) in each direction
  • PCP V.2.0. (0, 1, 2, or 4 words)
  • Interbus baudrate 500 kbit/s – 2 Mbit/s
  • Automatic slave address detection by controlling PLC master
  • 1x D-sub 9-pin male and 1x D-sub 9-pin female network connector
Order Code AB7883
Price groupC
Included components     Resource CD, USB configuration cable, Quick start guide, manuals. Anybus Configuration Manager software. For bulk pack orders, all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included)
Optional Accessories *Extra wide DIN-clip for flat mounting (Order Code SP1784)   
Guarantee3 years 

Especificaciones Tecnicas

Dimensions (L•W•H) 114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C or -13 to +149 °F
Storage temperature-40 to +85 °C or -40 to +185 °F
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector
Current consumption max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Referencia Descripcion
AB7883 Anybus X-gateway - CANopen Slave - Interbus CU Slave
Si continuas utilizando este sitio aceptas el uso de cookies. más información