Anybus X-gateway – CANopen Slave - PROFINET-IO Device

Características destacadas

  • Fast copying of cyclic I/O data between CANopen and PROFINET-IO networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
  • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
  • Optional control status information added to I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy

Descripción

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and PROFINET-IO networks.

FAST COPYING OF I/O DATA

The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as an Slave on the CANopen network and as an Device on the PROFINET-IO network. The data transmission between the two networks is completely transparent with a maximum data capacity of 512 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

CANopen Slave interface

CANopen Slave settings can be made either via on-board switches, or by importing the provided .EDS file into engineering tool of the controlling PLC.

  • Complete CANopen slave functionality according to CANopen Version 4.02
  • Max 512 bytes of Input and 512 bytes of Output data (PDO + SDO)
  • Customizable PDO mapping
  • Up to 80 RPDO’s and 80 TPDO’s
  • Transmission types: PDO Sync, Change-of-state, Event based and RTR
  • Network store/restore functionality
  • Heartbeat & Node Guarding support
  • Supports CANopen baudrates 10 kbit/s – 1 Mbit/s
  • CANopen configuration via .EDS file or via on-board rotary switches
  • 1x D-sub 9-pin male CANopen connector

PROFINET I/O Device/Slave interface 

PROFINET IO Device/Slave settings can be made by importing the provided .GSDML file into engineering tool of the controlling PLC. 

  • Complete PROFINET-IO Soft-Real-Time (RT) communication
  • Max 512 bytes of Input and 512 bytes of Output data
  • Up to 64 slots / 1 sub slot
  • Cyclic data exchange (10 ms cycle time)
  • Acyclic Data exchange (Record Data Requests) 
  • Baud rate 100 Mbit/s
  • Integrated FTP server provides easy file management using standard FTP clients
  • Web server with dynamic data capability and Server Side Include (SSI) capability
  • Email client with dynamic data capability and Event-triggered email handling
  • TCP/IP Configuration via DCP (Discovery and Configuration Protocol)
  • PROFINET uplink configuration via web interface or .GSDML file
  • 1x RJ45 network connector
Order Code  AB7658
Stock ItemYES
Included components             Resource CD, USB configuration cable, Quick start guide, manuals.  Anybus Configuration Manager software. Anybus OPC server software. (single-piece only) For bulk pack orders,all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included)
Optional Accessories *Extra wide DIN-clip for flat mounting (Order Code SP1784) Anybus IPconfig Tool - Utility for module TCP/IP configuration (Windows 32/64-bit)  Downloadable under "Files and Documentation"
Guarantee3 years 

Especificaciones Tecnicas

Dimensions (L•W•H) 114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C or -13 to +149 °F
Storage temperature-40 to +85 °C or -40 to +185 °F
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector
Current consumption max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Referencia Descripcion
AB7658 Anybus X-gateway – CANopen Slave - PROFINET-IO Device
Si continuas utilizando este sitio aceptas el uso de cookies. más información