CANtouch

Características destacadas

  • Supported protocols: CAN, CANopen, DeviceNet, SAE J1939
  • Baud rates (10 kBit/s ... 1 MBit/s)
  • Measurements designed as Apps
    - Bus Status (Bus traffic load)
    - Bus Errors (Active and passive frame errors)
    - Bus Voltages (CAN supply voltage and shield voltage)
    - Common Mode Voltage
    - CAN Levels (absolute / differential)
    - Bus Wiring (Short-circuits, interruptions, loop resistances, cable length)
    - Node Measurement (Quality level, Dist.-free voltage range, Edge steepness, Oscilloscope disp.)
    - Protocol Monitor
  • Including six apps, three additional apps via license

Descripción

Handheld diagnostic device for the physical and
logical analysis of CAN bus systems

CANtouch® is a battery-operated handheld diagnostic device for the physical and logical analysis of CAN, CANopen, DeviceNet or SAE J1939 systems.

Its state-of-the-art operation via touch screen provides intuitive and efficient handling similar to the operation of smart-phones. As a further development of the CAN-Bus-Tester 2, it possesses not only its functionality, but, in addition, provides new measuring functions. A simplified evaluation method based on a combination of traffic lights and smilies will assist you in quick assessment of the measurement results. Thanks to the integrated update option, you are already prepared for future extensions today. New functions can be enabled by purchasing additional licenses at any time.


Apps


Bus Status
Bus traffic detection (display: dominant, recessive, not defined, bus traffic) and bus traffic load (0 ... 100 %)




Bus Errors
Display of detected frame errors (active and passive error frames)



Bus Voltages
Display of the optional CAN supply voltage and the shield voltage


Common Mode Volt.
Recognition and measurement of the maximum voltage offset between the nodes



Differencial Voltage
Recognition and measurement of the differential CAN levels of all bus nodes




Absolute Voltage
Recognition and measurement of the absolute CAN levels of all bus nodes


Bus Wiring (optional license) 
Recognition and measurement of line short-circuits, line breaks, bus termination, loop resistances and the overall line length


Station Measurement (optional license) 
Station-related physical measurement of:
> Quality Value (Value representing the signal quality 0 ...100%)
> Disturbance-free voltage range and edge steepness
> Oscilloscope display with frame analysis and full frame recording


Protocol Monitor (optional license)
Transmission and reception of CAN Messages

Technical specifications

Languages English, German
Bus systems (CAN type) CAN (ISO11898-2), CANopen (CiA301), DeviceNet (EN 50325-2), SAE J1939
Bit scanning 64 times, 10240 sampling points
Supported baud rates > 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s;
> Additional user defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s;
> Automatic recognition via baud rate scan, bit timing adjustable
Power supply and battery > Built-in: Rechargeable lithium-ion battery
> External power supply: SELV DC 14 V; operation only via included 35 W wide range power supply
> Duration: Standby: up to 500 hrs.; Activated: Up to 36 hrs.; Measurements: up to 6 hrs.
> Charging times: fast charge to 80 % in about 1 hr.; fully charged in about 2 hrs.
Housing Aluminum housing, cover glass
Operating temperature 5 °C ... 40 °C
Protection IP20 according to EN 60529
Dimensions/Weight 186 x 102 x 37 mm; about 860 g

 


Orderinformation


Bundles

1.14.0415.00000 CANtouch Basic Kit consisting of:
- CANtouch with integrated lithium-ion battery
- Power supply, power cable (EURO), USB cable
- 2 manuals (German/English)
- 2 x CAN connection cables 0.3 m and 1.5 m
- 2 x T-adapter for 9-pin D-Sub and M12
- 2 x Termination resistor 9-pin D-Sub and M12
- 4 mm safety testing cable 3 m length with safety crocodile clip
- Case with foam for CANtouch, power supply, adapter set
1.14.0415.00001 CANtouch CANopen Bundle consisting of:
- CANtouch with integrated lithium-ion battery
- Power supply, power cable (EURO), USB cable
- 2 manuals (German/English)
- 2 x CAN connection cables 0.3 m and 1.5 m
- 2 x T-adapter for 9-pin D-Sub and M12
- 2 x Termination resistor 9-pin D-Sub and M12
- 4 mm safety testing cable 3 m length with safety crocodile clip
- Case with foam for CANtouch, power supply, adapter set
Software license files for the activation of:
- CAN - Node Measurement
- CANopen - Node Measurement
- Bus wiring measurement
- CAN protocol monitor (transmit/receive)
1.14.0415.00002 CANtouch DeviceNet Bundle consisting of:
- CANtouch with integrated lithium-ion battery
- Power supply, power cable (EURO), USB cable
- 2 manuals (German/English)
- 2 x CAN connection cables 0.3 m and 1.5 m
- 2 x T-adapter for 9-pin D-Sub and M12
- 2 x Termination resistor 9-pin D-Sub and M12
- 4 mm safety testing cable 3 m length with safety crocodile clip
- Case with foam for CANtouch, power supply, adapter set
Software license files for the activation of:
- CAN - Node Measurement
- DeviceNet - Node Measurement
- Bus wiring measurement
- CAN protocol monitor (transmit/receive)

 


Licenses for optional software modules

1.24.0415.20000 CAN - Node Measurement
1.24.0415.20001 CANopen - Node Measurement
1.24.0415.20002 DeviceNet - Node Measurement
1.24.0415.20003 SAE J1939 - Node Measurement
1.24.0415.20010 Bus wiring measurement
1.24.0415.20011 CAN protocol monitor (transmit/receive)

Related products

Especificaciones Tecnicas

Languages English, German
Bus systems (CAN type) CAN (ISO11898-2), CANopen (CiA301), DeviceNet (EN 50325-2), SAE J1939
Bit scanning 64 times, 10240 sampling points
Supported baud rates > 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s; > Additional user defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s; > Automatic recognition via baud rate scan, bit timing adjustable
Power supply and battery > Built-in: Rechargeable lithium-ion battery > External power supply: SELV DC 14 V; operation only via included 35 W wide range power supply > Duration: Standby: up to 500 hrs.; Activated: Up to 36 hrs.; Measurements: up to 6 hrs. > Charging times: fast charge to 80 % in about 1 hr.; fully charged in about 2 hrs.
Housing Aluminum housing, cover glass
Operating temperature 5 °C ... 40 °C
Protection IP20 according to EN 60529
Dimensions/Weight 186 x 102 x 37 mm; about 860 g

Referencia Descripcion
1.14.0415.00000 CANtouch
1.14.0415.00001 CANtouch
1.14.0415.00002 CANtouch
Documentacion Datasheet
Si continuas utilizando este sitio aceptas el uso de cookies. más información