Anybus X-gateway - CANopen Slave - CC-Link IE Field Slave
Características destacadas
- Fast copying of cyclic I/O data between the two networks (10-15 ms)
- Proven and tested with all PLC manufacturers
- Supports up to a maximum of 512 bytes of Input and Output data in each direction
- Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
- Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
- Optional control status information added to I/O data for diagnostic purposes
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
Descripción
The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CANopen and CC-Link IE Field networks.
FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Slave on both networks. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.
CANopen Slave interface
CANopen Slave settings can be made either via on-board switches, or by importing the provided .EDS file into engineering tool of the controlling PLC.
- Complete CANopen slave functionality according to CANopen Version 4.02
- Max 512 bytes of Input and 512 bytes of Output data (PDO + SDO)
- Customizable PDO mapping
- Up to 80 RPDO’s and 80 TPDO’s
- Transmission types: PDO Sync, Change-of-state, Event based and RTR
- Network store/restore functionality
- Heartbeat & Node Guarding support
- Supports CANopen baudrates 10 kbit/s – 1 Mbit/s
- CANopen configuration via .EDS file or via on-board rotary switches
- 1x D-sub 9-pin male CANopen connector
CC-Link IE Field interface
CC-Link IE Field Slave settings can be made either via on-board switches, or by importing the provided .CSP file into engineering tool of the controlling PLC.
- CC-Link IE Field interface of the X-gateway is conformance tested and approved by CLPA
- CC-Link Specification (Profile), publication BTP-05028-B
- Acts as a CC-Link IE Field Network Intelligent Device Station
- Max 512 bytes Input and 512 bytes I/O data
- On CC-Link IE Field: Max of 832 I/O points and 204 words Input and 832 I/O points and 204 words Output
- Baudrate 1 Gbit/s fixed operation
- TCP/IP settings configurable with web-page, Configuration Tool, DHCP or ARP
- CC-Link IE Field station setting via on-board switches
- 2x RJ-45 ports available simultaneously
Order Code | AB7963 |
Price group | A |
Included components | Resource CD, USB configuration cable, Quick start guide, manuals. Anybus Configuration Manager software. Anybus OPC server software. (single-piece only) For bulk pack orders,all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included) |
Optional Accessories | *Extra wide DIN-clip for flat mounting (Order Code SP1784) Anybus IPconfig Tool - Utility for module TCP/IP configuration (Windows 32/64-bit) Downloadable under "Files and Documentation" |
Guarantee | 3 years |
Especificaciones Tecnicas
Dimensions (L•W•H) | 114 x 44 x 127mm or 4,49 x 1,73 x 5,00" |
Weight | 400g or 0,880 lbs |
Operating temperature | -25 to +65 °C or -13 to +149 °F |
Storage temperature | -40 to +85 °C or -40 to +185 °F |
Power supply | 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector |
Current consumption | max. 400mA (Typical 200mA) |
Enclosure material | Aluminium and plastic |
Installation position | Vertical / Flat* |
Galvanic isolation | YES, on both BUS/Ethernet side |
Mechanical rating | IP20, NEMA rating 1 |
Mounting | DIN-rail (EN 50022 standard) |
I/O configuration | via USB port with Anybus Configuration Manager software |
Certifications | CE, CULUS, ATEX/Haz.Loc |
Referencia | Descripcion |
---|---|
AB7963 | Anybus X-gateway - CANopen Slave - CC-Link IE Field Slave |
Documentacion | Anybus X-gateway Datasheet |
Documentacion | Datasheet |
Documentacion | Installation Guide - CANopen Slave |
Documentacion | Installation Guide - CC-Link IE Field Slave |
Documentacion | Installation Guide Anybus X-gateway |
Documentacion | Network Guide - CANopen Slave |
Documentacion | Network Guide - CC-Link IE Field |
Documentacion | User Manual ABX |
Descargas | Anybus Configuration Manager X-gateway (for Win 7, Win 8, Win XP and Win 2000) |
Descargas | EDS Files For CANopen Slave |
Descargas | EU Declaration Of Conformity, ATEX Conformance Certificate |
Descargas | Firmware Download Tp |