Anybus Communicator CAN - DeviceNet
Características destacadas
- Saves machine builders and device manufacturers of integrating a DeviceNet interface
- Allows system integrators to retro-fit older CAN-based automation devices into DeviceNet communication structures
- Requires no hardware or software changes to be made to the connected device
- Compatible with all leading PLC's with DeviceNet support
- Performs complete CAN protocol conversion, no PLC function blocks required
- Flexible CAN frame building method for both Response/Request or Produce/Consume protocols
- Intelligent I/O data mapping within the Communicator permits even devices with slow CAN communication can be integrated without any restrictions to the upper network
- Always free technical support from HMS and our global Anybus Distributors
Descripción
Integrate your CAN-based industrial devices and equipment to a DeviceNet control system without the need for any changes to your device. Just connect, configure and you're done!
The Anybus Communicator is a proven and trusted protocol converter gateway that connects non- industrial devices with a CAN-based protocol to DeviceNet. The gateway performs an intelligent protocol conversion and presents the CAN data to the PLC/Controller as easily processed I/O data.
The Communicator is slim stand-alone gateway designed for IP20 and DIN-rail mounting, requiring a 24-volt power supply. The Communicator is conformance tested to current DeviceNet specifications guaranteeing network compatibility.
CONVERT ALMOST ANY TYPE OF CAN PROTOCOL
For industral devices with a CAN 2.0A or 2.0B port, HMS makes it possible to configure almost any Produce/Consume, Request/Response protocols with its flexible CAN frame building method. No proprietary configuration software is needed. All necessary configuration is performed using the Anybus Configuration Manager that accompanies the gateway.
TYPICAL CAN APPLICATIONS
Typical serial applications include variable frequency drives, sensors, actuators, human machine interfaces, barcode readers, RFID readers and industrial scales among others.
CAN configuration highlights - Anybus Configuration Manager
- Graphical CAN frame building support using several ready-made CAN functions.
- Can configure any CAN 2.0A or 2.0B based protocol (11 and 29 bit identifiers).
- Configures upto 128 transactions containing a total of 256 CAN frames
- Monitor/Modify function of process I/O data informing of CAN transaction status
- Diagnostic transaction Live List in the network I/O informing of CAN transaction status
- Multi-language support, supporting English, German, Spanish, Italian, French, Polish, Russian, Chinese and Japanese
- Handy Save/Load function allows for a completed configuration to be re-used for many other installations
- Password protection prevents unauthorized upload and download of configurations
DeviceNet interface features
- DeviceNet CONFORMANCE TESTED™ by ODVA
- DeviceNetNet Specification version: Communications Adapter profile 12
- Max. 512 bytes of Input and 512 bytes of Output data
- DeviceNet baudrate 125, 250, 500 kbit/s
- Supports I/O Slave messaging: Bit strobe, Polling, Cyclic, COS and Explicit Messaging
- MacID node address setting via DIP switch
- DeviceNet network configuration via .EDS file
- 1x 5-pin, 5.08 Phoenix plug connector
Order Code | AB7313 |
Included components | Anybus Configuration Manager CD, Quick start documentation, USB config cable and CAN D-sub connector is supplied with every single-piece Communicator shipment. (Power supply not included) |
Guarantee | 3 years |
Especificaciones Tecnicas
Dimensions (L•W•H) | 120 x 75 x 27mm or 4,72 x 2,95 x 1,06" |
Weight | 150g or 0,33 lbs |
Operating temperature | -25 to +55 °C or 0 to +131 °F |
Storage temperature | -40 to +85 °C or -40 to +185 °F |
Power supply | 24 VDC |
Current consumption | Typical 150mA |
Configuration port | USB (USB cable included) |
CAN connector | D-sub 9 Male (Included) |
Galvanic isolation | On both CAN and BUS/Ethernet side |
Mechanical rating | IP20, NEMA rating 1 |
Mounting | DIN-rail (EN 50022 standard) |
CAN baudrate | 20 kbit/s - 1 Mbit/s |
Protocol support | CAN 2.0A and 2.0B (11 and 29 bit identifiers) |
Certifications | CE, CULUS, ATEX/Haz.Loc |
Referencia | Descripcion |
---|---|
AB7313 | Anybus Communicator CAN - DeviceNet |
Documentacion | Anybus Communicator CAN Datasheet |
Documentacion | ATEX Conformance Certificate |
Documentacion | CE Declaration Of Conformity |
Documentacion | Datasheet |
Documentacion | EU Declaration of Conformity |
Documentacion | Firmware Download Anybus Communicator CAN |
Documentacion | How To Configure Anybus Communicator CAN To Consume SAE J1939 Messages |
Documentacion | Installation Guide |
Descargas | 2D and 3D drawings Anybus Communicator CAN |
Descargas | Anybus Communicator CAN Communicating With SEW Drives Using MOVILINK |
Descargas | Anybus Configuration Manager - Communicator CAN |
Descargas | EDS File For DeviceNet |
Descargas | Firmware Download Tp |
Descargas | Firmware Update Communicator CAN |
Descargas | How To Configure Anybus DeviceNet Slave Module With RSNetWorx For DeviceNet |
Descargas | How To Configure Communicator CAN - Video |