Anybus M-Bus to Modbus TCP gateway

Características destacadas

  • Get data on your consumption of electricity, water or gas onto a Modbus TCP network
  • Enable total overview of your site’s consumption, including building parameters (electricity, water, gas etc.) into a SCADA system
  • No hardware or software changes are required for the connected M-Bus device
  • Two versions available supporting connection up to 20 or 80 M-Bus slaves
  • Connect to other networks and PLC systems by combining with an Anybus X-gateway and access 10 additional industrial networks
  • Easy web-based configuration tool. No programming required.
  • Global free technical support and consultancy.

Descripción

The Anybus M-Bus to Modbus TCP gateway allows M-Bus devices to communicate on a Modbus TCP network. The gateway decodes M-Bus telegrams making it possible to map meter values to Modbus registers. This enables central control and supervision of measuring devices which usually use the M-Bus protocol.

Get a complete system overview

By getting data on consumed electricity, water, gas etc. straight into your PLC system, you can get a complete overview of your site in a SCADA system, including building parameters which otherwise have to be checked separately.

ACCESS OTHER NETWORKS - Pair with an Anybus X-gateway

You can also connect your M-Bus devices to any other industrial network by pairing the M-Bus gateway with an Anybus X-gateway for Modbus TCP. 

easy configuration - no programming required

The accompanying web-based configuration tool allows you to set up the gateway in an easy-to-use web interface. No programming is necessary.

M-Bus Master interface

  • M-Bus Master interface compliant with EN 13757-2
  • Connects either 20 or 80 M-Bus Slaves

 

Modbus TCP Server interface

  • Conforms to Modbus Appl. Protocol Spec. V1.1b,
  • 100 Mbit/s
Order CodeS  024380 (Up to 20 M-Bus Slaves) 025070 (Up to 80 M-Bus Slaves)
Included components     Quick start guide, manuals. (Power supply not included)
Required softwareIP-settings is made the configuration tool "CHIPtool" from Beck IPC Downloadable under "Files and Documentation" from this website
Guarantee3 years 

Especificaciones Tecnicas

Dimensions (L•W•H) 89 x 35 x 58 mm or 3,50 x 1,38 x 2.28 inches
Weight80g or 0,18 lbs
Operating temperature0 to +50 °C or 32 to +122 °F
Power supply24 ±5 VDC
Power consumption 2 W idle state, 10 W max.
Ethernet connector1x shielded RJ45 100 Mbit/s
M-Bus connector 5-pin screw terminal, max. 2.5mm²
Galvanic isolation On Ethernet side
Mechanical ratingIP20, Plastic housing
MountingDIN-rail (EN 50022 standard)
CertificationsCE