Anybus X-gateway – CC-Link Slave - Modbus TCP Server

Características destacadas

  • Fast copying of cyclic I/O data between the two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
  • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
  • Optional control status information added to I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy

Descripción

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CC-Link and Modbus TCP networks.

FAST COPYING OF I/O DATA

The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Slave/Server on both networks. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

CC-Link Slave interface

CC-Link Slave settings can be made either via on-board switches, or by importing the provided .CSP file into engineering tool of the controlling PLC.

  • Complete CC-Link slave Version 1 and 2 functionality
  • CC-Link Conformance BTP-05027-B specification
  • Transparent CC-Link communication (Standard Mode)
  • PLC Profile compliant communication (PLC profile mode)
  • Max. 896 bits/128 words (368 bytes) of I/O data in each direction
  • Supports CC-Link baudrates 156 kbit/s – 10 Mbit/s
  • Up to 4 occupied stations
  • Up to 8 extension cycles (version 2 only)
  • CC-Link configuration via on-board switches or via .CSP file
  • 1x 5-pin, 5.08 Phoenix plug network connector

Modbus TCP Slave interface

Modbus TCP Slave settings can be made either via the built-in web interface, or by importing the provided .EDS file into engineering tool of the controlling PLC.

  • Conforms to Modbus TCP v1.0
  • Modbus TCP class 0, class 1 and partially class 2 slave functionality
  • 10/100Mbit operation in full or half-duplex
  • Integrated FTP server provides easy file management using standard FTP clients
  • Web server with dynamic data capability and Server Side Include (SSI) capability
  • Email client with dynamic data capability and Event-triggered email handling
  • Per-user security framework
  • Quality of Service (QoS) available
  • DNS Capability
  • TCP/IP settings via DHCP/ARP/Anybus IPconfig (HICP)
  • Integrated switch allowing for a daisy-chain topology
  • 2x RJ-45 ports available simultaneously. 
Order Code  AB7643
Price groupA
Included components             Resource CD, USB configuration cable, Quick start guide, manuals.  Anybus Configuration Manager software. Anybus OPC server software. (single-piece only) For bulk pack orders,all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included)
Optional Accessories *Extra wide DIN-clip for flat mounting (Order Code SP1784) Anybus IPconfig Tool - Utility for module TCP/IP configuration (Windows 32/64-bit)  Downloadable under "Files and Documentation"
Guarantee3 years 

Especificaciones Tecnicas

Dimensions (L•W•H) 114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C or -13 to +149 °F
Storage temperature-40 to +85 °C or -40 to +185 °F
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector
Current consumption max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Referencia Descripcion
AB7643 Anybus X-gateway – CC-Link Slave - Modbus TCP Server