Anybus X-gateway – DeviceNet Scanner - PROFIBUS Slave
Características destacadas
- Fast copying of cyclic I/O data between two networks (10-15 ms)
- Proven and tested with all PLC manufacturers
- Supports up to a maximum of 512 bytes of Input and Output data in each direction
- Powerful Scanner interface for DeviceNet eliminates the need for a PLC controller
- Optional control and status information added to the I/O data for diagnostic purposes
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
Descripción
The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between DeviceNet and PROFIBUS networks.
FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Scanner on the DeviceNet network and a Slave on the PROFIBUS network. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.
DeviceNet Scanner/Master features
An Anybus X-gateway with an integrated DeviceNet Scanner interface can be used when there is no existing DeviceNet controlling PLC.
- DeviceNet CONFORMANCE TESTED™ by ODVA
- DeviceNetNet Specification version: Communications Adapter profile 12
- Supports up to 63 DeviceNet Adapter/Slaves
- Max. 512 bytes of Input and 512 bytes of Output data
- Optional Live List of the active status of the connected adapters
- DeviceNet baudrate 125, 250, 500 kbit/s
- Supports I/O Slave messaging: Bit strobe, Polling, Cyclic, COS and Explicit Messaging
- MacID node address setting via DIP switches
- DeviceNet Scanner/Adapter network configuration via in-built web interface or RSLogix/Studio5000 software
- 1x 5-pin, 5.08 Phoenix plug connector
PROFIBUS Slave interface
PROFIBUS Slave settings can be made either via on-board switches, or by importing the provided .GSD file into engineering tool of the controlling PLC.
- Complete PROFIBUS-DP/DPV1 Slave functionality according to extensions of EN 50170
- Supports Class 1 & Class 2 services
- Automatic baudrate detection up to 12Mbit/s
- Supports PA baud rate 45.45 kbit/s
- Max. Cyclic I/O data 244 bytes Input and 244 bytes Output, max 328 bytes total (in+out)
- Acyclic User Parameter data / Diagnostics length - up to 237 bytes
- Supports PROFIBUS features: Sync and Freeze and Watchdog
- PROFIBUS slave settings via on-board switches or vis .GSD file
- 1x D-sub 9-pin female PROFIBUS connector
Order Code | AB7663 |
Stock Item | YES |
Included components | Resource CD, USB configuration cable, Quick start guide, manuals. Anybus Configuration Manager software. For bulk pack orders, all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included) |
Optional Accessories | *Extra wide DIN-clip for flat mounting (Order Code SP1784) |
Guarantee | 3 years |
Especificaciones Tecnicas
Dimensions (L•W•H) | 114 x 44 x 127mm or 4,49 x 1,73 x 5,00" |
Weight | 400g or 0,880 lbs |
Operating temperature | -25 to +65 °C or -13 to +149 °F |
Storage temperature | -40 to +85 °C or -40 to +185 °F |
Power supply | 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector |
Current consumption | max. 400mA (Typical 200mA) |
Enclosure material | Aluminium and plastic |
Installation position | Vertical / Flat* |
Galvanic isolation | YES, on both BUS/Ethernet side |
Mechanical rating | IP20, NEMA rating 1 |
Mounting | DIN-rail (EN 50022 standard) |
I/O configuration | via USB port with Anybus Configuration Manager software |
Certifications | CE, CULUS, ATEX/Haz.Loc |
Referencia | Descripcion |
---|---|
AB7663 | Anybus X-gateway – DeviceNet Scanner - PROFIBUS Slave |
Documentacion | Anybus X-gateway Datasheet |
Documentacion | Conformance Certificate Profibus Slave |
Documentacion | Datasheet |
Documentacion | Firmware Download Anybus X-gateway Classic |
Documentacion | How To Configure DeviceNet With Anybus NetTool For DeviceNet |
Documentacion | Installation Guide - DeviceNet Scanner |
Documentacion | Installation Guide - PROFIBUS Slave Interface |
Documentacion | Installation Guide Anybus X-gateway |
Documentacion | Network Guide - DeviceNet Scanner |
Documentacion | Network Guide - PROFIBUS Slave |
Documentacion | User Manual ABX |
Descargas | Anybus Configuration Manager X-gateway (for Win 7, Win 8, Win XP and Win 2000) |
Descargas | Anybus NetTool for DeviceNet (Demo Version) |
Descargas | Drawings of X-gateway |
Descargas | EDS File For DeviceNet |
Descargas | EU Declaration Of Conformity, ATEX Conformance Certificate |
Descargas | Firmware Download Tp |
Descargas | GSD File For Profibus DP-DPV1 |
Descargas | How To Configure Anybus Profibus Slave Module With Siemens Step 7 |