Anybus X-gateway – EtherCAT Slave - Modbus RTU Slave

Características destacadas

  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy

Descripción

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between EtherCAT and Modbus RTU networks.

FAST COPYING OF I/O DATA

The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Slave on both networks. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

EtherCAT Slave interface

EtherCAT Slave settings can be made by importing the provided .XML file into engineering tool of the controlling PLC.

  • Complete EtherCAT slave according to DS 301 V4.022
  • Supports CANopen over EtherCAT
  • Max 512 bytes of Input and 512 bytes of Output data (PDO + SDO)
  • Baudrate 100 Mbit/s full duplex
  • 4 FMMU channels (can be used freely by the EtherCAT master for any purpose.)
  • 4 SM channels
  • Bit-oriented FMMU operation
  • Position addressing, node addressing and logical addressing
  • PDI Watchdog
  • Output I/O Sync Manager Watchdog
  • Integrated switch allowing for a daisy-chain topology
  • 2x RJ45 EtherCAT connectors

Modbus RTU Slave interface 

Modbus RTU network address settings made via on-board configuration switches 

  • Complete Modbus RTU slave functionality
  • Max 512 bytes of Input and 512 bytes of Output data
  • Modbus diagnostics support
  • Configuration via on-board DIP switches
  • Modbus RTU baudrate 12-57,6 kbit/s
  • 1x D-sub 9-pin female network connector
Order Code  AB76920
Price groupA
Included components             Resource CD, USB configuration cable, Quick start guide, manuals.  Anybus Configuration Manager software. For bulk pack orders,all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included)
Optional Accessories *Extra wide DIN-clip for flat mounting (Order Code SP1784) Anybus IPconfig Tool - Utility for module TCP/IP configuration (Windows 32/64-bit)  Downloadable under "Files and Documentation"
Guarantee3 years 

Especificaciones Tecnicas

Dimensions (L•W•H) 114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C or -13 to +149 °F
Storage temperature-40 to +85 °C or -40 to +185 °F
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector
Current consumption max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

Referencia Descripcion
AB76920 Anybus X-gateway – EtherCAT Slave - Modbus RTU Slave