Anybus X-gateway – EtherNet/IP Scanner - FIPIO Slave
Características destacadas
- Fast copying of cyclic I/O data between the two networks (10-15 ms)
- Proven and tested with all PLC manufacturers
- Powerful Scanner interface eliminates the need for a PLC controller on the EtherNet/IP network
- Supports up to a maximum of 512 bytes of Input and Output data in each direction
- Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
- Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
- Optional control status information added to I/O data for diagnostic purposes
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
Descripción
The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between EtherNet/IP and FIPIO networks.
FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Scanner on the EtherNet/IP network and a Slave on the FIPIO network. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.
EtherNet/IP Scanner/Master interface
An Anybus X-gateway with an integrated EtherNet/IP Scanner interface can be used when there is no existing EtherNet/IP controlling PLC. The X-gateway will perform EtherNet/IP Scanner functions.
- EtherNet/IP CONFORMANCE TESTED™ by ODVA
- Connects up 64 EtherNet/IP Adapter/Slaves
- 10/100Mbit operation in full or half-duplex
- Max. 509 bytes Input and 505 bytes Output data
- Optional Live List of the active status of the connected adapters
- Integrated FTP server provides easy file management using standard FTP clients.
- Web server with dynamic data capability and Server Side Include (SSI) capability
- Email client with dynamic data capability and Event-triggered email handling
- Support for CIP Objects
- DNS Capability
- TCP/IP settings via on-board DIP switches, DHCP/ARP/Anybus IPconfig (HICP)
- EtherNet/IP Scanner/Adapter network configuration via in-built web interface or RSLogix/Studio5000 software
- 1x RJ-45 Ethernet port
FIPIO Slave Interface
FIPIO Slave settings are made by on-board rotary switches
- Complete FIPIO functionality according to EN 50170
- FIPIO Extended Device Profile (FEDP), Class 01 0
- Max. 64 bytes (32 words) of Input and 64 bytes (32 words) of Output data
- FIPIO baudrate 1 Mbit/s
- FIPIO station address setting via rotary switches
- 1x D-sub 9-pin male network connector
Order Code | AB7674 |
Price group | C |
Included components | Resource CD, USB configuration cable, Quick start guide, manuals. Anybus Configuration Manager software. Anybus OPC server software. (single-piece only) For bulk pack orders,all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included) |
Optional Accessories | *Extra wide DIN-clip for flat mounting (Order Code SP1784) Anybus IPconfig Tool - Utility for module TCP/IP configuration (Windows 32/64-bit) Downloadable under "Files and Documentation" |
Guarantee | 3 years |
Especificaciones Tecnicas
Dimensions (L•W•H) | 114 x 44 x 127mm or 4,49 x 1,73 x 5,00" |
Weight | 400g or 0,880 lbs |
Operating temperature | -25 to +65 °C or -13 to +149 °F |
Storage temperature | -40 to +85 °C or -40 to +185 °F |
Power supply | 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector |
Current consumption | max. 400mA (Typical 200mA) |
Enclosure material | Aluminium and plastic |
Installation position | Vertical / Flat* |
Galvanic isolation | YES, on both BUS/Ethernet side |
Mechanical rating | IP20, NEMA rating 1 |
Mounting | DIN-rail (EN 50022 standard) |
I/O configuration | via USB port with Anybus Configuration Manager software |
Certifications | CE, CULUS, ATEX/Haz.Loc |
Referencia | Descripcion |
---|---|
AB7674 | Anybus X-gateway – EtherNet/IP Scanner - FIPIO Slave |
Documentacion | Anybus X-gateway Datasheet |
Documentacion | Datasheet |
Documentacion | Firmware Download Anybus X-gateway Classic |
Documentacion | Installation Guide - EtherNet-IP Scanner |
Documentacion | Installation Guide - FIP IO Slave |
Documentacion | Installation Guide Anybus X-gateway |
Documentacion | Network Guide - EtherNet-IP |
Documentacion | Network Guide - FIP IO Slave |
Documentacion | User Manual ABX |
Descargas | Anybus Configuration Manager X-gateway (for Win 7, Win 8, Win XP and Win 2000) |
Descargas | Drawings of X-gateway |
Descargas | EDS File For EtherNet-IP |
Descargas | EU Declaration Of Conformity, ATEX Conformance Certificate |
Descargas | Firmware Download Tp |
Descargas | How To Configure Anybus EtherNet-IP Scanner Module With RSNetWorx For EtherNet-IP |
Descargas | How To Configure Anybus FIPIO Slave Module With Schneider PL7 PLC |
Descargas | IPConfig - Utility for module TCP-IP configuration |