Cod: AB7877 - Nombre: Anybus X-gateway – FIPIO Slave - Modbus RTU Slave

Anybus
x-gateway-fips-mbrtu

Anybus X-gateway – FIPIO Slave - Modbus RTU Slave

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between FIPIO and Modbus RTU networks.

Características destacadas

  • Fast copying of cyclic I/O data between two networks (10-15 ms)
  • Proven and tested with all PLC manufacturers
  • Supports up to a maximum of 512 bytes of Input and Output data in each direction
  • Optional control and status information added to the I/O data for diagnostic purposes
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
Dimensions (L•W•H)  114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
Weight400g or 0,880 lbs
Operating temperature-25 to +65 °C  or  -13 to +149 °F 
Storage temperature-40 to +85 °C  or  -40 to +185 °F 
Power supply24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
Current consumption    max. 400mA (Typical 200mA)
Enclosure material Aluminium and plastic
Installation positionVertical / Flat*
Galvanic isolationYES, on both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
I/O configurationvia USB port with Anybus Configuration Manager software
CertificationsCE, CULUS, ATEX/Haz.Loc

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between FIPIO and Modbus RTU networks.

FAST COPYING OF I/O DATA

The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as an Slave on both networks. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

FIPIO Slave Interface

FIPIO Slave settings are made by on-board rotary switches

  • Complete FIPIO functionality according to EN 50170
  • FIPIO Extended Device Profile (FEDP), Class 01 0
  • Max. 64 bytes (32 words) of Input and 64 bytes (32 words) of Output data
  • FIPIO baudrate 1 Mbit/s
  • FIPIO station address setting via rotary switches
  • 1x D-sub 9-pin male network connector

Modbus RTU Slave interface 

Modbus RTU network address settings made via on-board configuration switches 

  • Complete Modbus RTU slave functionality
  • Max 512 bytes of Input and 512 bytes of Output data
  • Modbus diagnostics support
  • Configuration via on-board DIP switches
  • Modbus RTU baudrate 12-57,6 kbit/s
  • 1x D-sub 9-pin female network connector
Order Code AB7877
Price groupC
Included components     Resource CD, USB configuration cable, Quick start guide, manuals. Anybus Configuration Manager software. For bulk pack orders, all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included)
Optional Accessories *Extra wide DIN-clip for flat mounting (Order Code SP1784)   
Guarantee3 years 
Bienvenido a ER-Soft.
ER-Soft con la ley orgánica de protección de datos
Política de cookies.
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación.
Si continúa navegando, consideramos que acepta su uso.
Más información pulsando aquí
X

¿Necesitas ayuda? Click

ayuda ER-Soft
X
Consulta a ER-Soft. *

 

*

 

* *Campos obligatorios.




*Al enviar el formulario consideramos que esta de acuerdo, con nuestra política de datos. Ver política de datos
X