Anybus X-gateway - Lonworks Slave - Lonworks Slave
Características destacadas
- Fast copying of cyclic I/O data between the two Lonworks networks (10-15 ms)
- Proven and tested with all PLC manufacturers
- Supports up to a maximum of 512 bytes (256 LW variables) of Input and Output data in each direction
- Optional control and status information added to the I/O data for diagnostic purposes
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
Descripción
The Anybus X-gateway allows you to seamlessly inter-connect/extend PLC control systems and their connected devices on a Lonworks network.
FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two PLC systems. This offloads your PLC from working with additional calculations. The gateway acts as a Slave and provides a simple network extension. The data transmission is completely transparent with a maximum data capacity of 512 bytes (256 LW variables) in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.
Lonworks Slave interface
Lonworks network variables and configuration is made via an included configuration tool
- Certified for Lonmark application layer guidelines V3.2
- Lonworks FT-X1 Transceiver
- Up to 256 input + 256 output LonWorks Network Variables / Modbus Word Registers
- Amount and type of network variables configurable, data linking between Lonworks variables (SNVT's) and Modbus Registers
- Lonworks baudrate 78 kbit/s
- Includes LW Config Software Tool for Lonworks network setup
- 1x D-sub 9-pin male RS-232 configuration port
- 1x 5-pin, 5.08 Phoenix network connector
Order Code | AB7828 |
Price group | C |
Included components | Resource CD, USB configuration cable, Quick start guide, manuals. LW Config Tool Configuration software. For bulk pack orders, all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included) |
Optional Accessories | *Extra wide DIN-clip for flat mounting (Order Code SP1784) |
Guarantee | 3 years |
Especificaciones Tecnicas
Dimensions (L•W•H) | 114 x 44 x 127mm or 4,49 x 1,73 x 5,00" |
Weight | 400g or 0,880 lbs |
Operating temperature | -25 to +65 °C or -13 to +149 °F |
Storage temperature | -40 to +85 °C or -40 to +185 °F |
Power supply | 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector |
Current consumption | max. 400mA (Typical 200mA) |
Enclosure material | Aluminium and plastic |
Installation position | Vertical / Flat* |
Galvanic isolation | YES, on both BUS/Ethernet side |
Mechanical rating | IP20, NEMA rating 1 |
Mounting | DIN-rail (EN 50022 standard) |
I/O configuration | via USB port with Anybus Configuration Manager software |
Certifications | CE, CULUS, ATEX/Haz.Loc |
Referencia | Descripcion |
---|---|
AB7628 | Anybus X-gateway - Lonworks Slave - Lonworks Slave |
Documentacion | Anybus X-gateway Datasheet |
Documentacion | Datasheet |
Documentacion | Firmware Download Anybus X-gateway Classic |
Documentacion | Installation Guide - AS Interface Master |
Documentacion | Installation Guide - Modbus RTU Slave Interface |
Documentacion | Installation Guide Anybus X-gateway |
Documentacion | Network Guide - AS Interface Master |
Documentacion | Network Guide - Modbus RTU Slave |
Documentacion | User Manual Anybus X-gateway |
Descargas | Anybus Configuration Manager X-gateway (for Win 7, Win 8, Win XP and Win 2000) |
Descargas | Drawings of X-gateway |
Descargas | EU Declaration Of Conformity, ATEX Conformance Certificate |
Descargas | Firmware Download Tp |
Descargas | How To Configure Anybus AS-Interface Master Module |
Descargas | How To Configure Anybus Modbus RTU Slave Module With Unity Pro L |