Características destacadas 
                             - Monitor and control data on a J1939 heavy duty vehicle network from Modbus RTU PLC system or device 
- Typical applications: Electric Power Generation, Oil & Gas, Marine, Military, Heavy Duty Vehicles, Any Diesel Engine based system supporting J1939
- Max 500 bytes of I/O data in each direction
- Easy configuration via the included BWConfig Windows Software. No programming required
- Robust aluminum stand-alone housing 
- Global free technical support and consultancy
 Descripción 
                            
		The Anybus X-gateway J1939 Gateway provides connectivity between a Modbus RTU (serial) network and a J1939 Heavy Duty vehicle (CAN) network. The X-gateway appears as a Modbus Slave device allowing a Modbus Master to read or write data from the J1939 network.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
HMS provides the X-gateway with a free Windows based configuration tool (BWConfig). This PC based software allows the user to map J1939 parameter (PGN) data into a range of memory addressable through the Anybus X-gateway Modbus RTU interface.
 
Configuration of the X-gateway is simple using BWConfig and consists of setting up an I/O table containing selected J1939 PGNs and the rate that each will be read or written from the J1939 network. BWConfig will then automatically map the I/O table to a range of addresses accessible from the Anybus X-gateway Modbus RTU interface.
The configuration is downloaded from the PC to the Anybus X-gateway via an RS232 connection and is saved in FLASH memory.
	
		
	
		J1939 interface
    - SAE J1939 network interface with a unique network address in accordance to the J1939-81 specification
- Max 496 bytes of I/O Input data and 492 bytes of I/O Output Data
- Up to 120 PGN's monitored by Input data points
- Up to 100 PGN's  transmitted by Output data points  
- Supports J1939 network baud rates of 250K and 500K
- Transmission and reception of all types of fixed-length J1939 messages, including PDU1, PDU2, broadcast and destination specific
- Monitoring of DM1 (active diagnostics) and DM2 (previously active diagnostics) messages
- Complete network address management including address claim, protection, and yield on higher priority conflict
- Network address can be self-configurable over a range of addresses
-  J1939 Transport Protocol for transmission and reception of large messages (9 - 1785 bytes). Both connection based (RTS/CTS) and broadcast (BAM) are supported
-  Configurable CAN bus-off reset option will reset the network interface and attempt to return to online when a CAN bus-off condition is detected
- 1x 5-pole 5.08 mm Phoenix pluggable screw connector for J1939
Modbus RTU interface
    - Modbus RTU slave
- RS-485 half-duplex (2 wire) serial interface
- Configurable baud rates of 4800, 9600, and 19200 bps
- Configurable for no, odd, or even parity and 1 or 2 stop bits
- Support of all commonly used Modbus functions for reading and writing I/O data and diagnostics
- Overall module, Modbus, and J1939 status and diagnostics accessible through Modbus diagnostic functions and addressable registers.
| Order Code | AB7612 | 
| Price group | A | 
| Included components | Resource CD with "BWConfig" Windows software, Manuals, 
            RS-232 configuration cable, Installation Guide, 
            5-pole 5.08 mm Phoenix pluggable screw J1939 connector
            
            2-pole 5.08 mm Phoenix pluggable screw connector
            (Power supply not included) | 
| Order information
            USA & Canada | Please contact us-sales@anybus.com  +1 312 829 0601
            for ordering information within the USA and Canada | 
| Guarantee | 3 years |