Anybus X-gateway - Modbus TCP Client - CC-LinkSlave

Características destacadas

  • Fast copying of cyclic I/O data between a Modbus TCP and a CC-Link network (5 ms)
  • Allows for the integration of Modbus TCP based server/slave devices into other PLC control systems
  • Fulll Modbus TCP Client/Master functionality, eliminates the need for an PLC controller on the Modbus TCP network
  • Connects up to 64 Modbus Servers/Slave devices
  • Max I/O data capacity of 256 bytes in each direction
  • Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
  • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
  • SD memory card slot allows for backup, configuration and easy module replacement
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy

Descripción

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between Modbus TCP and CC-Link networks.

FAST COPYING OF I/O DATA

The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks.This offloads your PLC from working with additional calculations. The gateway acts as a Slave on the CC-Link network and as a full Master/Client on the Modbus TCP network. The data transmission between the two networks is completely transparent with a maximum I/O data capacity of 256 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

Configuration is made via Ethernet and a built-in web page. The configuration page is used to configure Ethernet TCP/IP settings, Modbus-TCP client/server configuration and I/O data size transfer between Modbus TCP and the chosen network.

Modbus TCP Client/Master interface

Modbus TCP Client and Server setup is made via an included visual web configuration interface without the need for any programming.

  • Modbus TCP Client functionality according to Modbus specification V1.1B 
  • Support for Modbus TCP functions 1, 2, 3, 4, 5, 6, 15, 16, 23
  • Connects up to 64 Modbus TCP servers/slaves
  • Supports up to max 256 bytes of Input and 256 bytes of Output data
  • 10/100Mbit operation in full or half-duplex
  • Integrated FTP server provides easy file management using standard FTP clients
  • Web server with dynamic data capability and Server Side Include (SSI) capability
  • Email client with dynamic data capability and Event-triggered email handling
  • Downlink Live List providing Modbus-TCP transaction status to uplink PLC
  • Control and Status words for downlink network control/status
  • Individual Modbus TCP server port number setting
  • Byte Swap feature
  • Full Modbus address range (1-65536)
  • Dual Modbus TCP RJ-45 ports available simultaneously
     

CC-Link Slave interface

CC-Link Slave settings can be made either via on-board switches, or by importing the provided .CSP file into engineering tool of the controlling PLC.

  • Complete CC-Link slave Version 1 and 2 functionality
  • CC-Link Conformance BTP-05027-B specification
  • Transparent CC-Link communication (Standard Mode)
  • PLC Profile compliant communication (PLC profile mode)
  • Max. 896 bits/128 words (368 bytes) of I/O data in each direction
  • Supports CC-Link baudrates 156 kbit/s – 10 Mbit/s
  • Up to 4 occupied stations
  • Up to 8 extension cycles (version 2 only)
  • CC-Link configuration via on-board switches or via .CSP file
  • 1x 5-pin, 5.08 Phoenix plug network connector
Order Code  AB9009
Included components             Resource CD, Quick start guide, manuals.  Anybus OPC server software. (single-piece only) For bulk pack orders,all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included)
Optional Accessories Wall mount bracket (Order Code 021520-B) 256 MB SD memory card (Industrial grade) (Order Code 021530-B) Anybus IPconfig Tool - Utility for module TCP/IP configuration (Windows 32/64-bit)  Downloadable under "Files and Documentation"
Guarantee3 years 

Especificaciones Tecnicas

Dimensions (L•W•H) 110 x 35 x 101 mm or 4,33 x 1,38 x 3,98"
Weight160g or 0,35 lbs
Operating temperature-25 to +70 °C or -13 to +158 °F
Storage temperature -40 to +85 °C or -40 to +185 °F
Power supply24 VDC
Current consumption Typical 150mA
USB portFor firmware upgrades
SD memory card slot For backup, configuration and easy replacement
Modbus TCP connector2x RJ45
Fieldbus/Ethernet connector(See the secondary network interface details above)
Galvanic isolation On both BUS/Ethernet side
Mechanical ratingIP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard) or Wall Mount (optional)
CertificationsCE, CULUS, ATEX/Haz.Loc

Referencia Descripcion
AB9009 Anybus X-gateway - Modbus TCP Client - CC-LinkSlave
Si continuas utilizando este sitio aceptas el uso de cookies. más información