Características destacadas
- Fast copying of cyclic I/O data between PROFIBUS and CC-Link networks (10-15 ms)
- Proven and tested with all PLC manufacturers
- Supports up to a maximum of 512 bytes of Input and Output data in each direction
- Optional control and status information added to the I/O data for diagnostic purposes
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
Descripción
The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between PROFIBUS and CC-Link networks.
FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as an Slave on the PROFIBUS network and as a Slave on the CC-Link network. The data transmission between the two networks is completely transparent with a maximum data capacity of 512 bytes in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.
PROFIBUS Slave interface
PROFIBUS Slave settings can be made either via on-board switches, or by importing the provided .GSD file into engineering tool of the controlling PLC.
- Complete PROFIBUS-DP/DPV1 Slave functionality according to extensions of EN 50170
- Supports Class 1 & Class 2 services
- Automatic baudrate detection up to 12Mbit/s
- Supports PA baud rate 45.45 kbit/s
- Max. Cyclic I/O data 244 bytes Input and 244 bytes Output, max 328 bytes total (in+out)
- Acyclic User Parameter data / Diagnostics length - up to 237 bytes
- Supports PROFIBUS features: Sync and Freeze and Watchdog
- PROFIBUS slave settings via on-board switches or vis .GSD file
- 1x D-sub 9-pin female PROFIBUS connector
CC-Link Slave interface
CC-Link Slave settings can be made either via on-board switches, or by importing the provided .CSP file into engineering tool of the controlling PLC.
- Complete CC-Link slave Version 1 and 2 functionality
- CC-Link Conformance BTP-05027-B specification
- Transparent CC-Link communication (Standard Mode)
- PLC Profile compliant communication (PLC profile mode)
- Max. 896 bits/128 words (368 bytes) of I/O data in each direction
- Supports CC-Link baudrates 156 kbit/s – 10 Mbit/s
- Up to 4 occupied stations
- Up to 8 extension cycles (version 2 only)
- CC-Link configuration via on-board switches or via .CSP file
- 1x 5-pin, 5.08 Phoenix plug network connector
Order Code | AB7852 |
Stock Item | YES |
Included components | Resource CD, USB configuration cable, Quick start guide, manuals. Anybus Configuration Manager software. For bulk pack orders, all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included) |
Optional Accessories | *Extra wide DIN-clip for flat mounting (Order Code SP1784) |
Guarantee | 3 years |
Especificaciones Tecnicas
Dimensions (L•W•H) | 114 x 44 x 127mm or 4,49 x 1,73 x 5,00" |
Weight | 400g or 0,880 lbs |
Operating temperature | -25 to +65 °C or -13 to +149 °F |
Storage temperature | -40 to +85 °C or -40 to +185 °F |
Power supply | 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector |
Current consumption | max. 400mA (Typical 200mA) |
Enclosure material | Aluminium and plastic |
Installation position | Vertical / Flat* |
Galvanic isolation | YES, on both BUS/Ethernet side |
Mechanical rating | IP20, NEMA rating 1 |
Mounting | DIN-rail (EN 50022 standard) |
I/O configuration | via USB port with Anybus Configuration Manager software |
Certifications | CE, CULUS, ATEX/Haz.Loc |
Referencia | Descripcion |
---|---|
AB7852 | Anybus X-gateway – PROFIBUS Slave - CC-Link Slave |
Documentacion | Anybus X-gateway Datasheet |
Documentacion | CC-Link Slave Conformance Certificate |
Documentacion | Conformance Certificate Profibus Slave |
Documentacion | Datasheet |
Documentacion | Firmware Download Anybus X-gateway Classic |
Documentacion | Installation Guide - CC-Link Slave |
Documentacion | Installation Guide - PROFIBUS Slave Interface |
Documentacion | Installation Guide Anybus X-gateway |
Documentacion | Network Guide - CC-Link Slave |
Documentacion | Network Guide - PROFIBUS Slave |
Documentacion | User Manual Anybus X-gateway |
Descargas | Anybus Configuration Manager X-gateway (for Win 7, Win 8, Win XP and Win 2000) |
Descargas | CSP Files For CC-Link Slave |
Descargas | Drawings of X-gateway |
Descargas | EU Declaration Of Conformity, ATEX Conformance Certificate |
Descargas | Firmware Download Tp |
Descargas | GSD File For Profibus DP-DPV1 |
Descargas | How To Configure Anybus Module With CC-Link And Mitsubishi PLC |
Descargas | How To Configure Anybus Profibus Slave Module With Siemens Step 7 |