ModGate Plus 413

Características destacadas

  • Controls 4 RS232 or RS422/485 devices located virtually anywhere via Ethernet, WLAN or Internet
  • Easy selection of RS232, RS422 or RS485 by single DIP switch or individually by software
  • Port expansion over USB A connector
  • LAN 1000/100/10 Ethernet auto-detect
  • NetCom Manager automatically finds NetCom+ devices in the network
  • Configuration over Driver Panels, serial Port, Telnet, WEB Browser, SNMP
  • Automatic mode switching between Driver and Raw Mode
  • Supports TCP/IP, UDP, Telnet, DHCP, ICMP, HTTP, SNMP V1/2c/3, DNS, PPP, openVPN
  • SSL/AES-256 encryption on Ethernet, WLAN and Internet
  • Optional: Wireless network IEEE 802.11b/g/n
  • Optional: 3G/4G Modem for mobile networks

Descripción

The Modgate Plus (or Modgate+) are easy to use Gateways from Modbus/TCP on Ethernet or WLAN to Modbus/RTU or Modbus/ASCII on the serial ports. Modgate+ 413 connects four Modbus serial lines to a network running TCP/IP. Metal case, wide temperature range and flexible DC power supply classify the Modgate+ as industrial-strength devices. They are based on a state-of-the-art RISC processor, to provide cost-effective design and low power consumption.

Using TCP/IP the Modgate+ operate without limitations on distance or OS platform, the Gateways are usable via Internet and VPN connections. The serial port is configured for Modbus/ASCII or Modbus/RTU and physically set to RS232, RS422 or RS485 operation. The messages received on the network are sent to the serial line, messages from the serial port are sent via network. Modgate+ automatically adjusts as Master or Slave on the serial port.
Modbus Master Multiplexing is implemented as an extension to the standard. Several masters connect to Modgate+ by Modbus/TCP, slaves on serial lines may answer requests from multiple masters.

The configuration of Modgate+ is done via browser. The user interface is based on Web 2.0 to provide an easy handling of the options. UPnP provides a simple and standard way to find the Gateway in the network.

Modgate+ devices can be ordered with an embedded module for WLAN 802.11b/g/n. Plus the Modgate+ 413 may be ordered as POE device, with additional power supply via Power-over-Ethernet 802.3af (Class 0).

Application
Secure Remote Monitoring SCADA system Building automation system Self-service banking system Industrial / Factory / Laboratory automation Automatic warehouse control system Wafer fabrication system Other remote and distributed serial devices control
6730ModGate Plus 413 (4x RS232/422/485)
Packing list

  • ModGate Plus 413
  • Mounting brackets for 19-inch rack
  • Wall mount plates
  • Terminal block for Power Supply
  • CD-ROM with user manual

Options
6689WLAN Kit internal internal module 802.11b/g/n, pigtail and antenna Purchase time option, not for later retrofitting
6690WLAN Kit external USB stick 802.11b/g/n, antenna
6031Power supply adapter 12V DC, 1A
661Serial Null-Modem adapter 9PF-9PF, change male to female
on RequestOption POE, 802.3af (Class 0)Power-over-Ethernet alternative supply
>Back to top

Especificaciones Tecnicas

Interface
Ethernet interface Auto-detecting 1000BaseT/100BaseTx/10BaseT (GigaLAN) Connector 8P8C (RJ45)
Wireless interface Optional via internal module or external USB stick IEEE 802.11b/g/n operation in Access Point or Client Mode
Protocols TCP/IP, DHCP, ICMP, HTTP, DNS, UDP, UPnP/SSDP, Modbus/TCP, Modbus/RTU, Modbus/ASCII
Serial interface RS232/422/485 selected by software
No. of port 4x DSUB 9 male connector (as PC)
Available Modes RS232 full duplexRS422 full duplexRS485 4 wire, full duplexRS485 2 wire, half duplex
Signals RS232: TxD,RxD, RTS,CTS, DTR,DSR, DCD, GNDRS422: Tx+/-, Rx+/-, GNDRS485 2 wire: Data+/-, GNDRS485 4 wire: Tx+/-, Rx+/-, GND
RS485 Data control Controlled by ART (Automatic Receive Transmit control)
Expansion port USB 2.0 High Speed, for WLAN
Serial Performance
Speed up to 115.2 kbps for Modbus RS232: up to 1000 kbps, RS422/485: up to 3 Mbps
Parity None, even, odd
Data bits 7, 8
Stop bits 1, 2
Operating Modes
Modbus RTU/ASCII Modbus RTU or Modbus ASCII protocol selected for each serial port individually
DirectMappingMode Direct mapping of Modbus addresses to serial ports or TCP connections
PromiscousMode Mapping of serial ports to TCP connections
Power and Environment
Connector 3-pin Terminal Block with Protective Earth
Power requirements 9 - 54V DC, 0.5A @ 12V, 6W
Power over Ethernet Optional, Class 0 Device (802.3af). Typical consumption is 6W.
Dimension 196×147×44 mm³ (W×L×H)
Operating Temp −20°C - 65°C
Storage Temp −20°C – 85°C
Case SECC sheet metal (1mm)
Weight 0.9kg
Mounting 19-inch RackWall mount
Special Features
Installation DIP switches set a defined temporary IP Address to contact via WEB Browser
Operating mode Promiscous ModeMessages received from the network are sent to defined serial ports, messages from the serial port are sent to defined connected network host.Mapped ModeReceived messages are scanned for their target address. This address is found in a table, the message is sent to the defined connection (serial or TCP).
Modbus Master Multiplexing An extension to the standard. Slaves on serial lines may answer requests from multiple masters. The masters connect to ModGate+ by Modbus/TCP.
Configuration Configuration over WEB Browser
Detection Announces presence in the network via Universal Plug and Play (UPNP) protocol
DNS Domain Name Server support
Serial Interface Serial Interface configurable by software This also enables internal Termination for RS485
Firmware Firmware update over WEB Browser
LEDs LEDs for Power, Ready, WLAN, serial Tx, Rx, Ethernet Link, Speed
Security
Password access Webinterface is password protected. The password can be changed in the Webinterface.

Referencia Descripcion
6730 ModGate Plus 413 (4x RS232/422/485) (ModGate 413)