Anybus Communicator CAN - EtherNet/IP
Características destacadas
- Saves machine builders and device manufacturers of integrating a CAN interface
- Allows system integrators to retro-fit older CAN-based automation devices into modern EtherNet/IP communication structures
- Requires no hardware or software changes to be made to the connected device
- Compatible with all PLCs with EtherNet/IP support
- Performs complete CAN protocol conversion, no PLC function blocks required
- Flexible CAN frame building method for both Response/Request or Produce/Consume protocols
- Intelligent I/O data mapping within the Communicator permits even devices with slow CAN communication can be integrated without any restrictions to the upper network
- Integrated Email client, FTP server and embedded webserver for diagnostics and data visualization
- Additional support for Modbus TCP Class 0, 1 and partial Class 2
- Always free technical support from HMS and our global Anybus Distributors
Descripción
Integrate your CAN-based industrial devices and equipment to a EtherNet/IP control system without the need for any changes to the device. Just connect, configure and you're done!
The Anybus Communicator is a proven and trusted protocol converter gateway that connects non- industrial devices with a CAN-based protocol to EtherNet/IP. The gateway performs an intelligent protocol conversion and presents the CAN data to the PLC/Controller as easily processed I/O data.
The Communicator is slim stand-alone gateway designed for IP20 and DIN-rail mounting, requiring a 24-volt power supply. The Communicator is conformance tested to current EtherNet/IP specifications guaranteeing network compatibility.
CONVERT ALMOST ANY TYPE OF CAN PROTOCOL
For industrial devices with a CAN 2.0A or 2.0B port, HMS makes it possible to configure almost any Produce/Consume, Request/Response protocols with its flexible CAN frame building method. No proprietary configuration software is needed. All necessary configuration is performed using the Anybus Configuration Manager that accompanies the gateway.
TYPICAL CAN APPLICATIONS
Typical CAN applications include variable frequency drives, sensors, actuators, human machine interfaces, barcode readers, RFID readers and industrial scales among others.
CAN configuration highlights - Anybus Configuration Manager
The Anybus Configuration Manager (ACM) is included with the purchase of the Anybus Communicator.
- Graphical CAN frame building support using several ready-made CAN functions.
- Can configure any CAN 2.0A or 2.0B based protocol (11 and 29 bit identifiers).
- Configures upto 128 transactions containing a total of 256 CAN frames
- Monitor/Modify function of process I/O data informing of CAN transaction status
- Diagnostic transaction Live List in the network I/O informing of CAN transaction status
- Multi-language support, supporting English, German, Spanish, Italian, French, Polish, Russian, Chinese and Japanese
- Handy Save/Load function allows for a completed configuration to be re-used for many other installations
- Password protection prevents unauthorized upload and download of configurations
EtherNet/IP interface features
- EtherNet/IP CONFORMANCE TESTED™ by ODVA
- EtherNet/IP Adapter Level 2 and Level 3 I/O Server CIP
- Max 509 bytes Input and 505 bytes Output data
- 10/100Mbit operation in full or half-duplex
- Device Level Ring (DLR) functionality available (announce-based ring participant)
- Per-user security framework
- Quality of Service (QoS) available
- TCP/IP settings can be configurable with web-page, Configuration Tool, DHCP or ARP
- Integrated switch allowing for a daisy-chain topology
- Dual RJ-45 ports available simultaneously
Order Code | AB7318 | |
Stock Item | YES | |
Included components | Anybus Configuration Manager CD, Quick start documentation, USB config cable and CAN D-sub connector is supplied with every single-piece Communicator shipment. (Power supply not included) | |
Guarantee | 3 years |
Especificaciones Tecnicas
Dimensions (L•W•H) | 120 x 75 x 27mm or 4,72 x 2,95 x 1,06" |
Weight | 150g or 0,33 lbs |
Operating temperature | -25 to +55 °C or 0 to +131 °F |
Storage temperature | -40 to +85 °C or -40 to +185 °F |
Power supply | 24 VDC |
Current consumption | Typical 150mA |
Configuration port | USB (USB cable included) |
CAN connector | D-sub 9 Male (Included) |
Galvanic isolation | On both CAN and BUS/Ethernet side |
Mechanical rating | IP20, NEMA rating 1 |
Mounting | DIN-rail (EN 50022 standard) |
CAN baudrate | 20 kbit/s - 1 Mbit/s |
Protocol support | CAN 2.0A and 2.0B (11 and 29 bit identifiers) |
Certifications | CE, CULUS, ATEX/Haz.Loc |
Referencia | Descripcion |
---|---|
AB7318 | Anybus Communicator CAN - EtherNet/IP |
Documentacion | Anybus Communicator CAN Datasheet |
Documentacion | ATEX Conformance Certificate |
Documentacion | EtherNet-IP Conformance Certificate |
Documentacion | EU Declaration of Conformity |
Documentacion | Firmware Download Anybus Communicator CAN |
Documentacion | How To Configure Anybus Communicator CAN To Consume SAE J1939 Messages |
Documentacion | Installation Guide |
Documentacion | User Manual |
Descargas | 2D and 3D drawings Anybus Communicator CAN |
Descargas | Anybus Communicator CAN Communicating With SEW Drives Using MOVILINK |
Descargas | Anybus Configuration Manager - Communicator CAN |
Descargas | Datasheet |
Descargas | EDS File For EtherNer-IP |
Descargas | Firmware Download Tp |
Descargas | Firmware Update Communicator CAN |
Descargas | How To Configure Communicator CAN - Video |
Descargas | IPConfig - Utility for module TCP-IP configuration |