Anybus Communicator CAN - Modbus RTU

Características destacadas

  • Saves machine builders and device manufacturers of integrating a Modbus RTU interface
  • Allows system integrators to retro-fit older CAN-based automation devices into Modbus RTU communication structures
  • Requires no hardware or software changes to be made to the connected device
  • Compatible with all PLCs with Modbus RTU support
  • Performs complete CAN protocol conversion, no PLC function blocks required
  • Flexible CAN frame building method for both Response/Request or Produce/Consume protocols
  • Intelligent I/O data mapping within the Communicator permits even devices with slow CAN communication can be integrated without any restrictions to the upper network
  • Always free technical support from HMS and our global Anybus Distributors

Descripción

Integrate your CAN-based industrial devices and equipment to a Modbus RTU control system without the need for any changes to the device. Just connect, configure and you're done!

The Anybus Communicator is a proven and trusted protocol converter gateway that connects non- industrial devices with a CAN-based protocol to Modbus RTU. The gateway performs an intelligent protocol conversion and presents the CAN data to the PLC/Controller as easily processed I/O data.

The Communicator is slim stand-alone gateway designed for IP20 and DIN-rail mounting, requiring a 24-volt power supply. The Communicator is conformance tested to current Modbus RTU specifications guaranteeing network compatibility.

CONVERT ALMOST ANY TYPE OF CAN PROTOCOL

For industral devices with a CAN 2.0A or 2.0B port, HMS makes it possible to configure almost any Produce/Consume, Request/Response protocols with its flexible CAN frame building method. No proprietary configuration software is needed. All necessary configuration is performed using the Anybus Configuration Manager that accompanies the gateway.

TYPICAL CAN APPLICATIONS

Typical serial applications include variable frequency drives, sensors, actuators, human machine interfaces, barcode readers, RFID readers and industrial scales among others.

Modbus RTU Slave interface features

  • Complete Modbus RTU slave functionality
  • Max 512 bytes of Input and 512 bytes of Output data
  • Coil and Register access
  • Configuration via on-board DIP switches
  • Modbus RTU baudrate 12-57,6 kbit/s
  • 1x D-sub 9 female network connector
Order Code  AB7316
Included components                         Anybus Configuration Manager CD, Quick start documentation, USB config cable and CAN D-sub connector is supplied with every single-piece Communicator shipment.  (Power supply not included)
Guarantee 3 years 

Especificaciones Tecnicas

Dimensions (L•W•H)120 x 75 x 27mm or 4,72 x 2,95 x 1,06"
Weight 150g or 0,33 lbs
Operating temperature-25 to +55 °C or 0 to +131 °F
Storage temperature -40 to +85 °C or -40 to +185 °F
Power supply 24 VDC
Current consumption Typical 150mA
Configuration portUSB (USB cable included)
CAN connector D-sub 9 Male (Included)
Galvanic isolation On both CAN and BUS/Ethernet side
Mechanical rating IP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
CAN baudrate20 kbit/s - 1 Mbit/s
Protocol support CAN 2.0A and 2.0B (11 and 29 bit identifiers)
Certifications CE, CULUS, ATEX/Haz.Loc

Referencia Descripcion
AB7316 Anybus Communicator CAN - Modbus RTU
Si continuas utilizando este sitio aceptas el uso de cookies. más información