Cod: AB7312 - Nombre: Anybus Communicator CAN - PROFIBUS

Anybus
Anybus Communicator Profibus

Anybus Communicator CAN - PROFIBUS

Integrate your CAN-based industrial devices and equipment to a PROFIBUS control system without the need for any changes to the device. Just connect, configure and you're done!

Características destacadas

  • Saves machine builders and device manufacturers of integrating a PROFIBUS interface
  • Allows system integrators to retro-fit older CAN-based automation devices into PROFIBUS communication structures
  • Requires no hardware or software changes to be made to the connected device
  • Compatible with all PLCs with PROFIBUS support
  • Performs complete CAN protocol conversion, no PLC function blocks required
  • Flexible CAN frame building method for both Response/Request or Produce/Consume protocols
  • Intelligent I/O data mapping within the Communicator permits even devices with slow CAN communication can be integrated without any restrictions to the upper network  
  • Always free technical support from HMS and our global Anybus Distributors
Dimensions  (L•W•H)120 x 75 x 27mm or 4,72 x 2,95 x 1,06"
Weight 150g or 0,33 lbs
Operating temperature-25 to +55 °C  or  0 to +131 °F 
Storage temperature -40 to +85 °C  or  -40 to +185 °F 
Power supply 24 VDC
Current consumption Typical 150mA
Configuration portUSB (USB cable included)
CAN connector  D-sub 9 Male (Included)
Galvanic isolation On both CAN and BUS/Ethernet side
Mechanical rating IP20, NEMA rating 1
MountingDIN-rail (EN 50022 standard)
CAN baudrate20 kbit/s - 1 Mbit/s
Protocol support CAN 2.0A and 2.0B (11 and 29 bit identifiers)
Certifications CE, CULUS, ATEX/Haz.Loc

Integrate your CAN-based industrial devices and equipment to a PROFIBUS control system without the need for any changes to the device. Just connect, configure and you're done!

The Anybus Communicator is a proven and trusted protocol converter gateway that connects non- industrial devices with a CAN-based protocol to PROFIBUS. The gateway performs an intelligent protocol conversion and presents the CAN data to the Master PLC/Controller as easily processed I/O data.

The Communicator is slim stand-alone gateway designed for IP20 and DIN-rail mounting, requiring a 24-volt power supply. The Communicator is conformance tested to current PROFIBUS specifications guaranteeing network compatibility.

Convert almost any type of CAN protocol

For industral devices with a CAN 2.0A or 2.0B port, HMS makes it possible to configure almost any Produce/Consume, Request/Response protocols with its flexible CAN frame building method. No proprietary configuration software is needed. All necessary configuration is performed using the Anybus Configuration Manager that accompanies the gateway.

Typical CAN applications

Typical serial applications include variable frequency drives, sensors, actuators, human machine interfaces, barcode readers, RFID readers and industrial scales among others. 

CAN configuration highlights - Anybus Configuration Manager

  • Graphical CAN frame building support using several ready-made CAN functions.
  • Can configure any CAN 2.0A or 2.0B based protocol (11 and 29 bit identifiers).
  • Configures upto 128 transactions containing a total of 256 CAN frames
  • Monitor/Modify function of process I/O data informing of CAN transaction status
  • Diagnostic transaction Live List in the network I/O informing of CAN transaction status
  • Multi-language support, supporting English, German, Spanish, Italian, French, Polish, Russian, Chinese and Japanese
  • Handy Save/Load function allows for a completed configuration to be re-used for many other installations
  • Password protection prevents unauthorized upload and download of configurations 

PROFIBUS interface features 

  • Complete PROFIBUS-DP slave according to IEC 61158
  • Max 244 bytes of Input and 244 bytes of Output data - 416 bytes data length in total
  • Automatic PROFIBUS baud rate detection (9600 bit / s - 12 Mbit / s)
  • Supports PROFIBUS features: Sync and Freeze and Watchdog
  • PROFIBUS uplink configuration via on-board switches or via .GSD file
  • 1x D-sub 9-pin female PROFIBUS connector
Order Code  AB7315  
Stock Item YES  
Included components Anybus Configuration Manager CD, Quick start documentation, USB config cable and CAN D-sub connector is supplied with every single-piece Communicator shipment.  (Power supply not included) 
Guarantee 3 years  
Bienvenido a ER-Soft.
ER-Soft con la ley orgánica de protección de datos
Política de cookies.
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación.
Si continúa navegando, consideramos que acepta su uso.
Más información pulsando aquí
X

¿Necesitas ayuda? Click

ayuda ER-Soft
X
Consulta a ER-Soft. *

 

*

 

* *Campos obligatorios.




*Al enviar el formulario consideramos que esta de acuerdo, con nuestra política de datos. Ver política de datos
X