Anybus X-gateway - Modbus TCP Client - CANopen Slave
Características destacadas
- Fast copying of cyclic I/O data between a Modbus TCP and a CANopen network (5 ms)
- Allows for the integration of Modbus TCP based server/slave devices into other PLC control systems
- Fulll Modbus TCP Client/Master functionality, eliminates the need for an PLC controller on the Modbus TCP network
- Connects up to 64 Modbus Servers/Slave devices
- Max I/O data capacity of 256 bytes in each direction
- Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
- Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
- SD memory card slot allows for backup, configuration and easy module replacement
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
Descripción
The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between Modbus TCP and CANopen networks.
FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks.This offloads your PLC from working with additional calculations. The gateway acts as a Slave on the CANopen network and as a full Master/Client on the Modbus TCP network. The data transmission between the two networks is completely transparent with a maximum I/O data capacity of 256 bytes in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
Configuration is made via Ethernet and a built-in web page. The configuration page is used to configure Ethernet TCP/IP settings, Modbus-TCP client/server configuration and I/O data size transfer between Modbus TCP and the chosen network.Modbus TCP Client/Master interface
Modbus TCP Client and Server setup is made via an included visual web configuration interface without the need for any programming.
- Modbus TCP Client functionality according to Modbus specification V1.1B
- Support for Modbus TCP functions 1, 2, 3, 4, 5, 6, 15, 16, 23
- Connects up to 64 Modbus TCP servers/slaves
- Supports up to max 256 bytes of Input and 256 bytes of Output data
- 10/100Mbit operation in full or half-duplex
- Integrated FTP server provides easy file management using standard FTP clients
- Web server with dynamic data capability and Server Side Include (SSI) capability
- Email client with dynamic data capability and Event-triggered email handling
- Downlink Live List providing Modbus-TCP transaction status to uplink PLC
- Control and Status words for downlink network control/status
- Individual Modbus TCP server port number setting
- Byte Swap feature
- Full Modbus address range (1-65536)
- Dual Modbus TCP RJ-45 ports available simultaneously
CANopen Slave interface
CANopen Slave settings can be made either via on-board switches, or by importing the provided .EDS file into engineering tool of the controlling PLC.
- Complete CANopen slave functionality according to CANopen Version 4.02
- Max 512 bytes of Input and 512 bytes of Output data (PDO + SDO)
- Customizable PDO mapping
- Up to 80 RPDO’s and 80 TPDO’s
- Transmission types: PDO Sync, Change-of-state, Event based and RTR
- Network store/restore functionality
- Heartbeat & Node Guarding support
- Supports CANopen baudrates 10 kbit/s – 1 Mbit/s
- CANopen configuration via .EDS file or via on-board rotary switches
- 1x D-sub 9-pin male CANopen connector
Order Code | AB9004 |
Included components | Resource CD, Quick start guide, manuals. Anybus OPC server software. (single-piece only) For bulk pack orders,all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included) |
Optional Accessories | Wall mount bracket (Order Code 021520-B) 256 MB SD memory card (Industrial grade) (Order Code 021530-B) Anybus IPconfig Tool - Utility for module TCP/IP configuration (Windows 32/64-bit) Downloadable under "Files and Documentation" |
Guarantee | 3 years |
Especificaciones Tecnicas
Dimensions (L•W•H) | 110 x 35 x 101 mm or 4,33 x 1,38 x 3,98" | |
Weight | 160g or 0,35 lbs | |
Operating temperature | -25 to +70 °C or -13 to +158 °F | |
Storage temperature | -40 to +85 °C or -40 to +185 °F | |
Power supply | 24 VDC | |
Current consumption | Typical 150mA | |
USB port | For firmware upgrades | |
SD memory card slot | For backup, configuration and easy replacement | |
Modbus TCP connector | 2x RJ45 | |
Fieldbus/Ethernet connector | (See the secondary network interface details above) | |
Galvanic isolation | On both BUS/Ethernet side | |
Mechanical rating | IP20, NEMA rating 1 | |
Mounting | DIN-rail (EN 50022 standard) or Wall Mount (optional) | |
Certifications | CE, CULUS, ATEX/Haz.Loc |
Referencia | Descripcion |
---|---|
AB9004 | Anybus X-gateway - Modbus TCP Client - CANopen Slave |
Documentacion | Anybus X-gateway Modbus TCP Datasheet |
Documentacion | CANopen Conformance Certificate |
Documentacion | Datasheet |
Documentacion | Firmware Download Anybus X-gateway Modbus-TCP |
Documentacion | Installation Guide |
Documentacion | User Manual |
Descargas | CAD Drawings 2D And 3D For Anybus X-gateway |
Descargas | EDS File For CANopen |
Descargas | EU Declaration Of Conformity, ATEX Certificate |
Descargas | Firmware Download Tp |
Descargas | Firmware Update X-gateway Modbus-TCP |
Descargas | How To Configure Anybus CANopen Slave Module with TwidoSoft |
Descargas | IPConfig - Utility for module TCP-IP configuration |