CANtouch
Características destacadas
- Supported protocols: CAN, CANopen, DeviceNet, SAE J1939
- Baud rates (10 kBit/s ... 1 MBit/s)
- Measurements designed as Apps
- Bus Status (Bus traffic load)
- Bus Errors (Active and passive frame errors)
- Bus Voltages (CAN supply voltage and shield voltage)
- Common Mode Voltage
- CAN Levels (absolute / differential)
- Bus Wiring (Short-circuits, interruptions, loop resistances, cable length)
- Node Measurement (Quality level, Dist.-free voltage range, Edge steepness, Oscilloscope disp.)
- Protocol Monitor - Including six apps, three additional apps via license
Descripción
Handheld diagnostic device for the physical and
logical analysis of CAN bus systems
CANtouch® is a battery-operated handheld diagnostic device for the physical and logical analysis of CAN, CANopen, DeviceNet or SAE J1939 systems.
Its state-of-the-art operation via touch screen provides intuitive and efficient handling similar to the operation of smart-phones. As a further development of the CAN-Bus-Tester 2, it possesses not only its functionality, but, in addition, provides new measuring functions. A simplified evaluation method based on a combination of traffic lights and smilies will assist you in quick assessment of the measurement results. Thanks to the integrated update option, you are already prepared for future extensions today. New functions can be enabled by purchasing additional licenses at any time.
Apps
Bus Status Bus traffic detection (display: dominant, recessive, not defined, bus traffic) and bus traffic load (0 ... 100 %) |
Bus Errors Display of detected frame errors (active and passive error frames) |
Bus Voltages Display of the optional CAN supply voltage and the shield voltage |
Common Mode Volt. Recognition and measurement of the maximum voltage offset between the nodes |
Differencial Voltage Recognition and measurement of the differential CAN levels of all bus nodes |
Absolute Voltage Recognition and measurement of the absolute CAN levels of all bus nodes |
Bus Wiring (optional license) Recognition and measurement of line short-circuits, line breaks, bus termination, loop resistances and the overall line length |
|
Protocol Monitor (optional license) Transmission and reception of CAN Messages |
Technical specifications
Languages | English, German |
Bus systems (CAN type) | CAN (ISO11898-2), CANopen (CiA301), DeviceNet (EN 50325-2), SAE J1939 |
Bit scanning | 64 times, 10240 sampling points |
Supported baud rates | > 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s; > Additional user defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s; > Automatic recognition via baud rate scan, bit timing adjustable |
Power supply and battery | > Built-in: Rechargeable lithium-ion battery > External power supply: SELV DC 14 V; operation only via included 35 W wide range power supply > Duration: Standby: up to 500 hrs.; Activated: Up to 36 hrs.; Measurements: up to 6 hrs. > Charging times: fast charge to 80 % in about 1 hr.; fully charged in about 2 hrs. |
Housing | Aluminum housing, cover glass |
Operating temperature | 5 °C ... 40 °C |
Protection | IP20 according to EN 60529 |
Dimensions/Weight | 186 x 102 x 37 mm; about 860 g |
Orderinformation
Bundles
1.14.0415.00000 | CANtouch Basic Kit consisting of: - CANtouch with integrated lithium-ion battery - Power supply, power cable (EURO), USB cable - 2 manuals (German/English) - 2 x CAN connection cables 0.3 m and 1.5 m - 2 x T-adapter for 9-pin D-Sub and M12 - 2 x Termination resistor 9-pin D-Sub and M12 - 4 mm safety testing cable 3 m length with safety crocodile clip - Case with foam for CANtouch, power supply, adapter set |
1.14.0415.00001 | CANtouch CANopen Bundle consisting of: - CANtouch with integrated lithium-ion battery - Power supply, power cable (EURO), USB cable - 2 manuals (German/English) - 2 x CAN connection cables 0.3 m and 1.5 m - 2 x T-adapter for 9-pin D-Sub and M12 - 2 x Termination resistor 9-pin D-Sub and M12 - 4 mm safety testing cable 3 m length with safety crocodile clip - Case with foam for CANtouch, power supply, adapter set Software license files for the activation of: - CAN - Node Measurement - CANopen - Node Measurement - Bus wiring measurement - CAN protocol monitor (transmit/receive) |
1.14.0415.00002 | CANtouch DeviceNet Bundle consisting of: - CANtouch with integrated lithium-ion battery - Power supply, power cable (EURO), USB cable - 2 manuals (German/English) - 2 x CAN connection cables 0.3 m and 1.5 m - 2 x T-adapter for 9-pin D-Sub and M12 - 2 x Termination resistor 9-pin D-Sub and M12 - 4 mm safety testing cable 3 m length with safety crocodile clip - Case with foam for CANtouch, power supply, adapter set Software license files for the activation of: - CAN - Node Measurement - DeviceNet - Node Measurement - Bus wiring measurement - CAN protocol monitor (transmit/receive) |
Licenses for optional software modules
1.24.0415.20000 | CAN - Node Measurement |
1.24.0415.20001 | CANopen - Node Measurement |
1.24.0415.20002 | DeviceNet - Node Measurement |
1.24.0415.20003 | SAE J1939 - Node Measurement |
1.24.0415.20010 | Bus wiring measurement |
1.24.0415.20011 | CAN protocol monitor (transmit/receive) |
Related products
Especificaciones Tecnicas
Languages | English, German |
Bus systems (CAN type) | CAN (ISO11898-2), CANopen (CiA301), DeviceNet (EN 50325-2), SAE J1939 |
Bit scanning | 64 times, 10240 sampling points |
Supported baud rates | > 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s; > Additional user defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s; > Automatic recognition via baud rate scan, bit timing adjustable |
Power supply and battery | > Built-in: Rechargeable lithium-ion battery > External power supply: SELV DC 14 V; operation only via included 35 W wide range power supply > Duration: Standby: up to 500 hrs.; Activated: Up to 36 hrs.; Measurements: up to 6 hrs. > Charging times: fast charge to 80 % in about 1 hr.; fully charged in about 2 hrs. |
Housing | Aluminum housing, cover glass |
Operating temperature | 5 °C ... 40 °C |
Protection | IP20 according to EN 60529 |
Dimensions/Weight | 186 x 102 x 37 mm; about 860 g |
Referencia | Descripcion |
---|---|
1.14.0415.00000 | CANtouch |
1.14.0415.00001 | CANtouch |
1.14.0415.00002 | CANtouch |
Documentacion | Datasheet |