iPC-I 320/104
Características destacadas
- Active CAN board with 8 bit micro controller
- Common driver interface for easy exchange of the PC interface type
- Features filtering, preprocessing, time stamped storage of CAN messages
- Galvanic isolated CAN interface
Descripción
Active PC/104 board
1 x CAN (High-Speed)
The iPC-I 320/104 is an active CAN board with one CAN channel which is appropriate for a wide variety of CAN applications. Filtering, preprocessing, transmission and time-stamped storage of the CAN messages are just some of the features offered by the on-board microcontroller.
This product is not recommended for new developments (Last time buy: March 30, 2017). For new developments we recommend to use the successor product IXXAT PC-I 04/104.Fields of application
The iPC-I 320/104 is suitable for demanding PC-based applications which require e.g. data preprocessing. The board is supported by the IXXAT driver packages and higher layer protocol APIs as well as by the IXXAT tool suite. A detailed software support overview can be found here.
Technical specifications
PC bus interface | PC/104 bus, 8 bit |
PC address range | C000h-FE00h (memory mapped), adjustable in 8 kB steps |
Interrupts | IRQ 3, 4, 5, 6, 7, 9, 10, 11, 12, 14, 15 |
Microcontroller | Dallas DS80C320 |
CAN controller | SJA 1000; CAN 2.0 A/B |
CAN bus interface | ISO 11898-2, bent 2 x 5 pin connector according to DS 102 |
Power supply | 5 V DC, 190 mA typ. |
Galvanic isolation | 1 kV, 1 sec. |
Temperature range | -40 ºC ... +85 ºC |
Certification | CE, CSA/UL |
Size | Approx. 90 x 96 mm |
Contents of delivery
- PC/CAN interface card, manual
- CAN driver VCI for Windows 2000, XP, Vista, Windows 7
- Simple CAN monitor "miniMon"
Order number
1.01.0043.10200 | iPC-I 320/104; one CAN channel with galvanic isolation |
Especificaciones Tecnicas
PC bus interface | PC/104 bus, 8 bit |
PC address range | C000h-FE00h (memory mapped), adjustable in 8 kB steps |
Interrupts | IRQ 3, 4, 5, 6, 7, 9, 10, 11, 12, 14, 15 |
Microcontroller | Dallas DS80C320 |
CAN controller | SJA 1000; CAN 2.0 A/B |
CAN bus interface | ISO 11898-2, bent 2 x 5 pin connector according to DS 102 |
Power supply | 5 V DC, 190 mA typ. |
Galvanic isolation | 1 kV, 1 sec. |
Temperature range | -40 ºC ... +85 ºC |
Certification | CE, CSA/UL |
Size | Approx. 90 x 96 mm |
Referencia | Descripcion |
---|---|
1.01.0043.10200 | iPC-I 320/104 Active PC/104 board |
Documentacion | Dsatasheet |