Anybus X-gateway – CANopen Master – PROFIBUS Slave
Características destacadas
- Fast copying of cyclic I/O data between a CANopen and PROFIBUS network (5 ms)
- Fulll CANopen Master/Manager functionality, eliminates the need for an PLC controller on the CANopen network
- Connects up to 126 CANopen slave devices
- Proven and tested with all PLC manufacturers
- Easy CANopen configuration via the included Anybus Configuration Manager software. No programming required
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
Descripción
The Anybus X-gateway CANopen provides a seamless connection between a PROFIBUS network and a secondary CANopen sub-network. This makes it possible to integrate CANopen devices into a PROFIBUS PLC system.
FAST COPYING OF I/O DATA
The X-gateway's primary function is fast transfer of cyclic I/O data between the two networks. I/O data from the PROFIBUS network is written into CANopen objects that can be mapped into CANopen PDOs and vice versa. The gateway acts as a full Master/Manager on the CANopen network and as a Slave on the PROFIBUS network. The data transmission between the two networks is completely transparent with a maximum data capacity of 510 bytes in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
CANopen configuration can easily be made through the included Anybus Configuration Manager CANopen software, or with any other standard CANopen configuration tool. No programming skills are needed.
CANopen Master/Manager Interface
- CANopen Master/Manager implementation according to the CANopen specification DS301 v4.0.2.
- Connects up to 126 CANopen slaves
- Network Management (NMT) messages, to configure and initialize the network.
- Supporting 128 Receive PDOs and 128 Transmit PDOs, each can transfer up to 8 bytes.
- Up to 510 bytes of cyclic data in each direction (PDO)
- PDO message types: COS (Change of State), Cyclic Synchronous, Acyclic Synchronous.
- Synchronization Object (SYNC) is used for synchronizing PDO communication.
- Heartbeat Mechanism to monitor the status of nodes.
- Node Guarding/Life Guarding Protocol provides possibility to guard slaves or the master.
- EMCY (Emergency Object) is used for error reporting.
- LSS master functionality
- Can also function as a CANopen Slave
PROFIBUS Slave interface
PROFIBUS Slave settings can be made either via on-board switches, or by importing the provided .GSD file into engineering tool of the controlling PLC.
- Complete PROFIBUS-DP/DPV1 Slave functionality according to extensions of EN 50170
- Supports Class 1 & Class 2 services
- Automatic baudrate detection up to 12Mbit/s
- Supports PA baud rate 45.45 kbit/s
- Max. Cyclic I/O data 244 bytes Input and 244 bytes Output, max 328 bytes total (in+out)
- Acyclic User Parameter data / Diagnostics length - up to 237 bytes
- Supports PROFIBUS features: Sync and Freeze and Watchdog
- PROFIBUS slave settings via on-board switches or vis .GSD file
- 1x D-sub 9-pin female PROFIBUS connector
Order Code | AB7301 |
Included components | Resource CD, Quick start guide, manuals. Anybus Configuration Manager CANopen software. For bulk pack orders, all configuration software can be downloaded under "files and documentation" from this website. (Power supply not included) |
Optional Accessories | USB-CAN configuration adapter (Order Code 012670) |
Guarantee | 3 years |
Especificaciones Tecnicas
Dimensions (L•W•H) | 120 x 75 x 27mm or 4,72 x 2,95 x 1,06" | |
Weight | 150g or 0,33 lbs | |
Operating temperature | -25 to +55 °C or 0 to +131 °F | |
Storage temperature | -40 to +85 °C or -40 to +185 °F | |
Power supply | 24 VDC | |
Current consumption | Typical 150mA | |
Configuration port | USB (USB to CAN cable not included) | |
Configuration Switches | On-board for CANopen node address and baud rate setting | |
CANopen connector | D-sub 9 Male (Included) | |
Fieldbus/Ethernet connector | (See interface details above) | |
Galvanic isolation | On both CAN and BUS/Ethernet side | |
Mechanical rating | IP20, NEMA rating 1 | |
Mounting | DIN-rail (EN 50022 standard) | |
CANopen baudrate | 20 kbit/s - 1 Mbit/s | |
Certifications | CE, CULUS, ATEX/Haz.Loc |
Referencia | Descripcion |
---|---|
AB7301 | Anybus X-gateway – CANopen Master – PROFIBUS Slave |
Documentacion | Anybus X-gateway CANopen Datasheet |
Documentacion | CANopen Conformance Certificate |
Documentacion | Datasheet |
Documentacion | EU-Declaration of Conformity X-gateway CANopen |
Documentacion | How To Use The Live List Functionality Of The Anybus X-gateway CANopen Module |
Documentacion | Installation Guide Anybus X-gateway |
Documentacion | Installation Guide |
Documentacion | User Manual ABX |
Documentacion | User Manual |
Descargas | 2D And 3D Drawings X-gateway CANopen |
Descargas | Anybus Configuration Manager - CANopen |
Descargas | Anybus X-gateway CANopen Master (Video) |
Descargas | EDS File For CANopen (Secondary Network) |
Descargas | Firmware Download Tp |
Descargas | Firmware Update X-gateway CANopen |
Descargas | GSD File For PROFIBUS |
Descargas | How To Configure Anybus Profibus Slave Module With Siemens Step 7 |
Descargas | How to configure Anybus X-gateway CANopen Master |
Descargas | How To Configure CANopen Network Using Anybus X-gateway CANopen Master (Video) |