Analizadores y simuladores de Bus de campo
Analizadores y simuladores de Bus de campo
Código: 1.14.0415.00002
Handheld diagnostic device for the physical and
logical analysis of CAN bus systems
CANtouch® is a battery-operated handheld diagnostic device for the physical and logical analysis of CAN, CANopen, DeviceNet o
- Supported protocols: CAN, CANopen, DeviceNet, SAE J1939
- Baud rates (10 kBit/s ... 1 MBit/s)
- Measurements designed as Apps
- Bus Status (Bus traffic load)
- Bus Errors (Active and passive frame errors)
- Bus Voltages (CAN supply voltage and shield voltage)
- Common Mode Voltage
- CAN Levels (absolute / differential)
- Bus Wiring (Short-circuits, interruptions, loop resistances, cable length)
- Node Measurement (Quality level, Dist.-free voltage range, Edge steepness, Oscilloscope disp.)
- Protocol Monitor
- Including six apps, three additional apps via license
Languages | English, German
|
Bus systems (CAN type) | CAN (ISO11898-2), CANopen (CiA301), DeviceNet (EN 50325-2), SAE J1939
|
Bit scanning | 64 times, 10240 sampling points
|
Supported baud rates | > 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s;
> Additional user defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s;
> Automatic recognition via baud rate scan, bit timing adjustable
|
Power supply and battery | > Built-in: Rechargeable lithium-ion battery
> External power supply: SELV DC 14 V; operation only via included 35 W wide range power supply
> Duration: Standby: up to 500 hrs.; Activated: Up to 36 hrs.; Measurements: up to 6 hrs.
> Charging times: fast charge to 80 % in about 1 hr.; fully charged in about 2 hrs.
|
Housing | Aluminum housing, cover glass
|
Operating temperature | 5 °C ... 40 °C
|
Protection | IP20 according to EN 60529
|
Dimensions/Weight | 186 x 102 x 37 mm; about 860 g
|
CANtouch
Código: 1.12.0157.00000
Powerful CANopen service and diagnostics
tool for service staff and developers
The IXXAT CANopen® Device Manager is a versatile and upgradeable tool aimed at device test, diagnostics, and field service tasks. Built aroun
- Comprehensive CANopen functionality including NMT node and error control services, SDO client, PDO consumer and producer
- Support for SDO block transfer
- LSS master functionality according to CiA 305
- Configuration and firmware download according to CiA 302
- Customized plug-in modules covering dedicated CANopen diagnostics or service functionality
CANopen Device Manager
Código: 1.12.0360.90000
Configuration editor and code generator for J1939 projects
The SAE J1939 Designer is a powerful tool for creating and management of J1939 projects. A J1939 project consists of the definition of parameters (SPNs) and mes
- Enables cross product configuration and code generation
- Increase the development speed by avoiding errors caused by inconsistent data sets
- Supports canAnalyser, SAE J1939 API and SAE J1939 protocol software (together with the extensions)
- Supports the single and multi instance version of the J1939 protocol software
- Allows an easy configuration of the protocol software exactly to the needs of the application
- Provides an application specific user interface on parameter level for the protocol software
- Allows the definition of proprietary messages and parameters via a comfortable graphical user interface
SAE J1939 Designer
Código: 1.24.0034.03100
EtherNet/IP Scanner Simulator Tool
EIPScan is a Microsoft Windows-based software application that simulates an EtherNet/IP Scanner. EIPScan is an extremely useful tool for testing and debugging EtherNet/IP products during dev
- Connect to devices through one or more Ethernet interfaces on the PC
- Browse the network(s) for devices or manually add them
- View and modify I/O data (binary or hexadecimal)
- Automated test of Class 1 and Class 3 connections
- Queuing of multiple UCMM Requests
EIPScan
Código: FRC-EP170
The Embedded Platform forms the basis for manifold automotive testing and analysis applications in vehicles and test benches – both, with the IXXAT ACT tools as well as with customer-specific software solutions.
FlexRay A/B channel (also available as CAN-only version without FlexRay) | 1 x (10 MBit/s)
|
CAN High Speed | max. 4 x
|
CAN Low Speed | max. 1 x
|
LIN | 1 x
|
K-Line | 1 x
|
RS232 | 1 x
|
USB | 2 x (Host and Device)
|
Digital in | 4 x
|
Digital out | 4 x
|
SDHC card slot | 1 x
|
Internal expansion slots | 2 x mPCIe form factor
|
External extensions | Wi-Fi, USB devices
|
Others | Prepared: GSM/GPS, Bluetooth and Automotive Ethernet
|
PC connection | Ethernet 10/100 MBit/s, Wi-Fi or USB 2.0
|
Plugs | Standard plug for PC; DSub plug for fieldbus
|
Temperature range | -40 °C ... +80 °C
|
Power supply | 6-36 V DC; 350 mA typ. at 12 V
|
Dimensions | 142 x 113 x 40 mm
|
FRC-EP 170
Código: FRC-EP190
The Embedded Platform forms the basis for manifold automotive testing and analysis applications in vehicles and test benches – both, with the IXXAT ACT tools as well as with customer-specific software solutions.
FlexRay A/B channel | 2 x (10 MBit/s)
|
CAN High Speed | max. 8 x
|
CAN Low Speed | max. 2 x
|
CAN FD | max. 2 x
|
LIN | 2 x
|
K-Line | 2 x
|
RS232 | 1 x
|
USB | 2 x (Host and Device)
|
Digital in | max. 4 x
|
Digital out | max. 4 x
|
Analog in (12 bit) | max. 4 x
|
Further interfaces | optional EtherCAT-Slave I/O
|
SDHC card slot | 1 x
|
Internal expansion slots | 2 x (FlexRay, CAN, CAN-FD, EtherCAT)
|
External extensions | Wi-Fi, USB devices
|
Others | Prepared: GSM/GPS, Bluetooth and Automotive Ethernet
|
PC connection | Ethernet 10/100 MBit/s, Wi-Fi or USB 2.0
|
Plugs | Standard plug for PC; DSub plug for fieldbus
|
Temperature range | -40 °C ... +80 °C
|
Power supply | 6-36 V DC; 420 mA typ. at 12 V
|
Dimensions | 182 x 113 x 50 mm
|
FRC-EP 190
Código: 1.12.0133.31000
Powerful Tool for Development, Testing and Service
The canAnalyser is a versatile tool for the development, testing and servicing of CAN, CAN FD and LIN based systems. The software package is based on a modular concept and a
- Interfaz intuitiva y configurable.
- Análisis de redes fácil e intuitivo, almacenamiento de datos en el disco duro
- Potente y versátil, con time-stamp de alta precisión en las tramas CAN
- Permite Análisis posterior en modo offline
canAnalyser lite/standard
Código: 1.12.0166.31000
Powerful Tool for Development, Testing and Service
The canAnalyser is a versatile tool for the development, testing and servicing of CAN, CAN FD and LIN based systems. The software package is based on a modular concept and a
- Interfaz intuitiva y configurable.
- Análisis de redes fácil e intuitivo, almacenamiento de datos en el disco duro
- Potente y versátil, con time-stamp de alta precisión en las tramas CAN
- Permite Análisis posterior en modo offline
canAnalyser lite/standard
Código: 1.12.0145.30000
CANopen Interpreter for canAnalyser
As an addition to the canAnalyser, the CANopen Module interprets all received CAN messages according to the CANopen specifications CiA301 (incl. SDO block transfer), CiA302 (incl. Flying Maste
- Simplifies analysis of CANopen networks and devices
- Direct display of all CANopen messages according to CANopen specification
- Easy integration into canAnalyser test environment
CANopen Module
Código: 1.12.0148.30000
DeviceNet Interpreter for canAnalyser
As an addition to the canAnalyser, the DeviceNet module interprets all received CAN messages according to the ODVA DeviceNet standard and displays the received parameters according to Messag
- Simplifies analysis of DeviceNet networks and devices
- Direct display of all DeviceNet messages according to DeviceNet specification
- Easy integration into canAnalyser test environment
DeviceNet Module
Código: 1.12.0149.30000
SAE J1939 Interpreter for canAnalyser
As an addition to the canAnalyser, the J1939 Module provides the display of received messages according to the SAE J1939 notation. This includes the interpretation of received J1939 messages
- Simplifies analysis of SAE J1939 networks and devices
- Direct display of all SAE J1939 messages according to SAE J1939 specification
- Easy integration into canAnalyser test environment
J1939 Module
Código: 1.01.0097.00000
Installation tester for CAN networks
CANcheck allows users to analyze CAN networks during commisioning, maintenance and helps searching faults. This battery-operated, hand-held device connects to the CAN network t
- Cable test with network switched off and operational test with network switched on
- Wiring test: test of the resistances between all pins of the CAN-connector (assignment in accordance with CiA), providing assessment based on pre-defined threshold values
- Terminal resistance test: measurement of the resistance between CAN_H and CAN_L
- Cable length: measurement of cable length via pulse-time delay, cable impedance
- Measurement of the signal level: absolute and differential signal level listed according to identifier
- Baud rate detection: detection of baud rate of the tested CAN system
- Identifier scan: determination of all identifiers transmitted and display of reception frequency
- CANopen mode: Signal level and reception frequency listed according to node-ID
- Bus load: measurement of the current bus load of the CAN system
- Error frames: number of error frames per time unit
- User’s guide: test instructions before the test, OK or error message after the test, continuation after acknowledgement
- Multilingual: test instructions in German or English
Display | 128 x 64 pixels; background light can be switched on or off
|
Keypad | Touch-sensitive keypad with 6 keys
|
Switch on/off | Switch on by pressing any key; switches off automatically after 10 mins.
|
USB port | USB 2.0 (full speed)
|
CAN interface | ISO 11898-2 High-Speed CAN
|
Power supply | 4 x 1.5 V Mignon Battery (AA) or USB
|
Operating time | approximately 24 hrs. with a battery capacity of 2850 mAh
|
Temperature range | 0 ºC ... +50 ºC
|
Housing and dimensions | Sturdy aluminum housing 116 x 160 x 34 mm (W/H/D)
|
CANcheck
Código: 1.14.0415.00000
Handheld diagnostic device for the physical and
logical analysis of CAN bus systems
CANtouch® is a battery-operated handheld diagnostic device for the physical and logical analysis of CAN, CANopen, DeviceNet o
- Supported protocols: CAN, CANopen, DeviceNet, SAE J1939
- Baud rates (10 kBit/s ... 1 MBit/s)
- Measurements designed as Apps
- Bus Status (Bus traffic load)
- Bus Errors (Active and passive frame errors)
- Bus Voltages (CAN supply voltage and shield voltage)
- Common Mode Voltage
- CAN Levels (absolute / differential)
- Bus Wiring (Short-circuits, interruptions, loop resistances, cable length)
- Node Measurement (Quality level, Dist.-free voltage range, Edge steepness, Oscilloscope disp.)
- Protocol Monitor
- Including six apps, three additional apps via license
Languages | English, German
|
Bus systems (CAN type) | CAN (ISO11898-2), CANopen (CiA301), DeviceNet (EN 50325-2), SAE J1939
|
Bit scanning | 64 times, 10240 sampling points
|
Supported baud rates | > 10; 20; 50; 100; 125; 250; 500; 800; 1000 kbit/s;
> Additional user defined: 5; 33.3; 62.5; 75; 83.3; 200 kbit/s;
> Automatic recognition via baud rate scan, bit timing adjustable
|
Power supply and battery | > Built-in: Rechargeable lithium-ion battery
> External power supply: SELV DC 14 V; operation only via included 35 W wide range power supply
> Duration: Standby: up to 500 hrs.; Activated: Up to 36 hrs.; Measurements: up to 6 hrs.
> Charging times: fast charge to 80 % in about 1 hr.; fully charged in about 2 hrs.
|
Housing | Aluminum housing, cover glass
|
Operating temperature | 5 °C ... 40 °C
|
Protection | IP20 according to EN 60529
|
Dimensions/Weight | 186 x 102 x 37 mm; about 860 g
|
CANtouch
Código: 1.14.0402.00001
Powerful tool for analysis of
CAN bus physics and CAN protocol
The CAN-Bus-Tester 2 is a universal measuring instrument for the commissioning, analysis, monitoring, troubleshooting and maintenance of CAN bus systems.
- Support of CAN, CANopen, DeviceNet and SAE J1939 systems
- Analysis of the signal-to-noise ratio of all telegrams (level, flanks, faults)
- Integrated oscilloscope with data interpretation for telegram analysis
- Comprehensive trigger conditions for fault localization (logical and physical errors)
- Monitoring of bus status, bus load, error telegrams
- Wiring test (termination resistance, short circuits, interruptions, loop resistance, line length)
- Automatic baud rate detection
- Simple connection to CAN systems thanks to automatic baud rate detection and BusScan
- Simple operation via Windows program
- Simple generation of test protocols
- CAN monitor for transmission and reception of CAN messages (optional)
Use | CAN according to ISO 11898-2 (High-Speed) with 11-bit or 29-bit identifier (CAN 2.0A and 2.0B)
|
Baudrate | 5 k, 10 k, 20 k, 33.3 k, 50 k, 62.5 k, 75 k, 83.3 k, 100 k, 125 k, 200 k, 250 k, 500 k, 800 k, 1000 kBit/s
|
Baudrate detection | All supported baudrates
|
Bit scanning | 64x, 10240 scanning points
|
Trigger output | BNC-socket, electrically isolated
|
Connection to CAN bus | Passive, 2 x 9-pole SUB-D connector
|
PC connection | Via USB, electrically isolated
|
Supply voltage | 9 ... 36 V DC, DIN 45323 low-voltage socket; 0.15 ... 0.55A
|
Dimensions and wight | 40 x 134 x 170 mm (H/W/L), approx. 600 g; With case: 504 x 354 x 119 mm, approx. 5000 g
|
Safety/protection | EN 60950: 2003-03 / IP 20 according to EN 60529
|
EMC | EN 61000-3-2: 2000, +A1: 2000, +A2: 2004
EN 55022: 1998, +A1: 2000, +A2: 2003
EN 61000-6-2: 2001
|
Temperatur range | Operation: +5 °C ... +40 °C; Storage: -20 °C ... +60 °C
|
CAN-Bus-Tester 2 (CBT2)
Código: 1.14.0402.00002
Powerful tool for analysis of
CAN bus physics and CAN protocol
The CAN-Bus-Tester 2 is a universal measuring instrument for the commissioning, analysis, monitoring, troubleshooting and maintenance of CAN bus systems.
- Support of CAN, CANopen, DeviceNet and SAE J1939 systems
- Analysis of the signal-to-noise ratio of all telegrams (level, flanks, faults)
- Integrated oscilloscope with data interpretation for telegram analysis
- Comprehensive trigger conditions for fault localization (logical and physical errors)
- Monitoring of bus status, bus load, error telegrams
- Wiring test (termination resistance, short circuits, interruptions, loop resistance, line length)
- Automatic baud rate detection
- Simple connection to CAN systems thanks to automatic baud rate detection and BusScan
- Simple operation via Windows program
- Simple generation of test protocols
- CAN monitor for transmission and reception of CAN messages (optional)
Use | CAN according to ISO 11898-2 (High-Speed) with 11-bit or 29-bit identifier (CAN 2.0A and 2.0B)
|
Baudrate | 5 k, 10 k, 20 k, 33.3 k, 50 k, 62.5 k, 75 k, 83.3 k, 100 k, 125 k, 200 k, 250 k, 500 k, 800 k, 1000 kBit/s
|
Baudrate detection | All supported baudrates
|
Bit scanning | 64x, 10240 scanning points
|
Trigger output | BNC-socket, electrically isolated
|
Connection to CAN bus | Passive, 2 x 9-pole SUB-D connector
|
PC connection | Via USB, electrically isolated
|
Supply voltage | 9 ... 36 V DC, DIN 45323 low-voltage socket; 0.15 ... 0.55A
|
Dimensions and wight | 40 x 134 x 170 mm (H/W/L), approx. 600 g; With case: 504 x 354 x 119 mm, approx. 5000 g
|
Safety/protection | EN 60950: 2003-03 / IP 20 according to EN 60529
|
EMC | EN 61000-3-2: 2000, +A1: 2000, +A2: 2004
EN 55022: 1998, +A1: 2000, +A2: 2003
EN 61000-6-2: 2001
|
Temperatur range | Operation: +5 °C ... +40 °C; Storage: -20 °C ... +60 °C
|
CAN-Bus-Tester 2 (CBT2)
Actualmente estamos trabajando en mostrarte los mejores resultados, si no encuentras el producto que buscas contacta con nosotros a través de
info@er-soft.com o al número
Tel. +34 916-408-408